12. Appendix
12.1 FAQs
QUESTION
Is it possible to connect two
heating circuits to one "Uni-
box TQ-RTL R-Tronic"?
How many m² of temperature
balance surface can be con-
nected to the "Unibox TQ-RTL
R-Tronic"?
102273880-V01.08.2019
RESPONSE
Yes, use a"Duo connection piece" to connect two heating
circuits of the same length to one "Unibox TQ-RTL R-Tronic".
Each surface temperature balance circuit may have a maximum
pipe length of 80 m, provided you use 16/17 mm pipes.
Illust. 14: Connection scheme of two heating circuits with "Duo
connection piece"
You can connect a surface covering approximately 20 m² per
"Unibox TQ-RTL R-Tronic". The pipe length must not exceed
100 m when using a 17 mm pipe.