If the Air Conditioner continues to blow the fuse,
have an electrician check the starting amperage
and running amperage on the unit. If the fuse
continues to blow and the electrical consumption
is found to be normal, it will require the
replacement of the faulty fuse.
If all electrical power to the Air Conditioner is
normal but neither the fan or the compressor will
operate, the connector plug located behind the
ceiling assembly control box should be checked
to determine whether it is faulty.
C. Mechanical Integrity – The Air Conditioner should
be inspected periodically to be sure that the bolts
which secure the unit to the roof are tight and in
good shape. Also, an examination of the plastic
shroud covering the Air Conditioner on the top of
the roof should be made periodically. Be sure the
four mounting screws and washers are snug and
holding the shroud to the Air Conditioner. Also,
examine the shroud to be sure it is not developing
cracks or has suffered damage from impact.
XI. WARRANTY SERVICE
Let's face it. Sometimes even the best products
may need service. To obtain warranty service on
your Coleman-Mach Air Conditioner, please
contact your selling dealer, or you may access
our web site on the Internet at www.Airxcel.com
for answers to the most frequently asked
questions and service center locations.
Airxcel, Inc. support help may be accessed by e-
mail at RVPSupport@Airxcel.com. All written
correspondence should be directed to:
AIRXCEL, INC. - RV Products Division
P.O. Box 4020
Wichita, KS 67204
1.
Carefully
WARRANTY, the OPTIONAL THREE YEAR
EXTENDED PARTS WARRANTY, sample
contract, terms, conditions, exceptions and
exclusions
www.Airxcel.com.
2. An optional three year extended parts only
contract is available at an additional cost of
$89.95. To obtain this optional three year parts
contract, fill out the application located on the
back of this manual. Once completed, cut along
the dotted lines and mail the application and
your check or money order to the address
above. Applications must be made within
ninety (90) days of the original purchase.
7. Inquiries
Conditioner must include the model and serial
numbers and the date of purchase. The model
and serial numbers can be found on the I.D.
label located on the Air Conditioner basepan
return air opening at the bottom of the roof unit.
This information may also be found on the Air
Conditioner rating plate.