Download Print this page

Biddle HR 12 Manual page 55

Advertisement

HR 12 M
ANUAL
Manual version 1.0 (15-07-2018)
1. Remove the inspection panels 1.
2. Dry the drip tray 2.
3. Remove the filter 3.
4. Remove the plug 8 of the bypass damper.
5. Lower the cross bar as follows:
Caution:
c
The exchanger 4 and the bypass 5 will also lower.
Caution:
c
The drip tray 2 turns downwards.
-
Unscrew the side bolts 6 slightly.
Danger:
d
However, leave the bolts secure.
-
Slowly unscrew the long bolts 7 and remove them.
6. Tip the cross bar to make space.
7. Remove the bypass 5.
8. Remove the exchanger 4.
9. Clean the exchanger by spraying it with water.
10. Return all components to their places in reverse order.
Note:
n
Return the drip tray back above the cross bar in
time.
Note:
n
Connect the plug of the bypass damper once again
before you replace the filter (in the correct
direction).
en
S
ERVICE
en-55