Download Print this page
Weltem Amps WPC-5000 Owner's Manual

Weltem Amps WPC-5000 Owner's Manual

Portable air conditioners
Hide thumbs Also See for Amps WPC-5000:

Advertisement

Quick Links

Owner's Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, oper-
ate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and / or property damage! Retain instructions for future reference.
Portable Air Conditioners
Description
Weltem Portable Air Conditioners feature spot cooling for large
areas where cooling of the entire area is not practical. A dedi-
cated spot cooling thermostat controls the unit in this applica-
tion. These air conditioners can also be used in smaller areas
for room cooling.
A control panel provides ease of use and contains a self-diag-
nostic function and display, showing operating modes, room
and set temperatures, and faults. If an abnormal operation oc-
curs, a visual display of the fault is shown. Caster wheels are
included for easy portability.
Suitable applications include: a factory or work place, industrial
kitchen, computer room, emergency cooling, outdoor event,
etc.
Unpacking
After unpacking the unit, carefully inspect unit for any damage that may have occurred during
transit. Check for any loose, missing, or damaged parts.
Specifications
Model No.
WPC-5000
Model No.
WPC-5000
20.5 x 26.4 x 41 (523 x 671 x 1042)
Model No.
WPC-5000
Owner's Manual
Power Supply Ph-V-Hz
Single Phase, 230V, 50Hz
Dimensions
W x D x H - in. (mm)
Power cord
Amp
10
Cooling Capacity
Btu/h
21,000
Weight (Net / Gross)
(kg)
88 / 94
Condensate tank
Gallons(Liters)
3.17 (12)
1
WPC-5000
WPC-5000
WPC-5000
Figure 1
Power Consumption
Watts
2,100
Rated Current
Amps
9.5
Ambient temperature
range °F( °C)
64~113(18~45)

Advertisement

loading
Need help?

Need help?

Do you have a question about the Amps WPC-5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Weltem Amps WPC-5000

  • Page 1 / or property damage! Retain instructions for future reference. Portable Air Conditioners Description Weltem Portable Air Conditioners feature spot cooling for large areas where cooling of the entire area is not practical. A dedi- cated spot cooling thermostat controls the unit in this applica- tion.
  • Page 2 Owner’s Manual WPC-5000 Specifications (Continued) Setting temperature Setting temperature Model No. (Room cool mode) °F( °C) ((Spot cool mode) °F( °C) WPC-5000 64~86 (18~30) 32~86 (0~30) Application Area No. of Cool Air Wheels Model No. (Room cool mode) ft²(m²) Outlets Pcs pcs / diameter WPC-5000 538 (50)
  • Page 3 Owner’s Manual WPC-5000 DO NOT operate the unit in explosive or flammable environments. 14. DO NOT use the plug to start and to stop the unit. Always use the control panel to start and to stop the unit. 15. Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet.
  • Page 4 Owner’s Manual WPC-5000 Assembly (WPC-4000) COMPONENT PARTS Cool air outlet hose Top fan exhaust flange Display / Control board Evaporator / filter Condenser / filter Guide bar for condensate water tank Condensate water tank (Water level is Electrical access panel sensed, and the unit opera on is stopped when tank is full.
  • Page 5 Owner’s Manual WPC-5000 Installation WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where flammable gas leakage may occur. Do not use the unit in areas where it will be exposed to rain or water. Do not use the unit in a corrosive atmosphere.
  • Page 6 Owner’s Manual WPC-5000 Operation CONTROL PANEL Figure 8 1. POWER BUTTON: Activates unit when POWER BUTTON is pressed. (Fan starts on low speed). If power button is pressed during operation, unit stops. 2. BLOWER BUTTON: Changes fan speed from (Low) to (High) when pressed. 3.
  • Page 7 Owner’s Manual WPC-5000 Maintenance FILTER CLEANING (See Figures 9 and 10) There are two filters in the unit. The evaporator filter is located at the front of the unit. The condenser filter is located at the side of the unit. 1.
  • Page 8 Owner’s Manual WPC-5000 Maintenance (Continued) – To ensure your product is covered by warranty, the complete faulty product along with your original purchase receipt must be provided at the place of purchase. Product Portable Air Conditioner Customer: Please read and keep this Model No.
  • Page 9 Owner’s Manual WPC-5000 SELF-DIAGNOSTIC ALARM CODES Alarm Display Problem Cause Corrective Action • Indoor heat • Do not use the air exchanger tempera- Frost prevention conditioner if ambient ture too low sensor and Abnormal temperature is lower • TH3 temperature temperature sensor than 18°C (64°F) sensor has a loose...
  • Page 10 Owner’s Manual WPC-5000 Wiring Diagram DRAIN PUMP (option) Figure 12 - Circuit Wiring Diagram (WPC-5000)
  • Page 11 Owner’s Manual WPC-5000 Troubleshooting chart Symptom Possible Cause(s) Corrective Action High water level in con- 1. Remove blockage from drain densate tank hose Water leakage 2. Remove any object stuc un- deerneath of the black panel nuder the water tank 1.
  • Page 12 Technical Advice and Recommendations, Disclaimer. Notwithstanding any past practice or dealings or trade custom, sales shall not include the furnishing of technical advice or assistance or system design. Weltem as- sumes no obligations or liability on account of any unauthorized recommendations, opinions or advice as to the choice, installation or use of products.