Descripti on
Weltem Portable Air Conditi oners feature spot cooling for
large areas where cooling of the enti re area is not practi cal.
A dedicated spot cooling thermostat controls the unit in this
applicati on.
These air conditi oners can also be used in smaller areas for
room cooling.
A control panel provides ease of use and contains a self-diag-
nosti c functi on and display, showing operati ng modes, room
and set temperatures, and faults.
If an abnormal operati on occurs, a visual display of the fault is
shown. Caster wheels are included for easy portability. Suitable
applicati ons include: a factory or work place, computer room,
emergency cooling, etc.
Unpacking
Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during
transit. Check for any loose, missing, or damaged parts.
Specifi cati ons
Model
Cooling Capacity
WPC - 6000
25,000BTU ( 7.3Kw )
Depth / Width/ Height
Model
/ Weight
561 / 747 / 1202 (mm)
WPC - 6000
/ 106kg
Refrigerant
Electrical supply
R410A (910g)
230V, 1phase, 50hz
Fan speeds
Air flow (high/low)
757 / 664 CFM
2
1
WPC-6000
Figure 1
Rated Current
Power Consumption
Amps
Watts
12.6 A
Noise level at 3m
Operating range
(high/low)
Below 70 dBA
WPC-6000
2.9 kW
18~45°C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WPC-6000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Weltem WPC-6000

  • Page 1 / or property damage! Retain instructions for future reference. Portable Air Conditioners Descripti on Weltem Portable Air Conditi oners feature spot cooling for large areas where cooling of the enti re area is not practi cal. A dedicated spot cooling thermostat controls the unit in this applicati on.
  • Page 2 Owner’s Manual WPC-6000 “Original instructions” General Safety Information Please read this manual carefully for instructions on correct installation and usage. Please read all safeguards. 1. Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first use.
  • Page 3 Owner’s Manual WPC-6000 DO NOT operate a unit with a damaged power cord. 19. The filters must be used with the product at all times. When the filters are removed for clean- ing, always ensure that the unit has been turned off and unplugged from the electrical outlet.
  • Page 4 Owner’s Manual WPC-6000 Assembly (WPC-6000) COMPONENT PARTS Cool air outlet hose Top fan exhaust flange Display / Control board Condenser / filter Evaporator / filter Guide bar for condensate water tank Condensate water tank (Water level is Electrical access panel...
  • Page 5: Installation

    Owner’s Manual WPC-6000 Installation WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where flammable gas leakage may occur. Do not use the unit in areas where it will be exposed to rain or water.
  • Page 6: Operation

    Owner’s Manual WPC-6000 Operation CONTROL PANEL Figure 8 1. POWER BUTTON: Activates unit when POWER BUTTON is pressed. (Fan starts on low speed). If power button is pressed during operation, unit stops. 2. BLOWER BUTTON: Changes fan speed from (Low) to (High) when pressed.
  • Page 7: Maintenance

    Owner’s Manual WPC-6000 Maintenance FILTER CLEANING (See Figures 9 and 10) There are two filters in the unit. The evaporator filter is located at the front of the unit. The condenser filter is located at the side of the unit.
  • Page 8: Spring Replacement

    Owner’s Manual WPC-6000 Maintenance (Continued) – To ensure your product is covered by warranty, the complete faulty product along with your original purchase receipt must be provided at the place of purchase. Product Portable Air Conditioner Customer: Please read and keep this Model No.
  • Page 9 Owner’s Manual WPC-6000 SELF-DIAGNOSTIC ALARM CODES Alarm Display Problem Cause Corrective Action • Indoor heat • Do not use the air exchanger tempera- Frost prevention conditioner if ambient ture too low sensor and Abnormal temperature is lower • TH3 temperature temperature sensor than 18°C (64°F)
  • Page 10: Wiring Diagram

    N - 2 RELAY RELAY Spark Arrestor (Motor) Detail "A" Figure 12 - Circuit Wiring Diagram (WPC-6000) 2017 1. 재질 : 은무데드롱 25미크론 2017 2. 인쇄방법: 씨링인쇄 3. 인쇄색상: 흑색 1도 4. 표면처리: 라미네이팅(OPP코팅) 5. 인쇄기준 : 도면 및 설계 제공 필름...
  • Page 11: Troubleshooting Chart

    Owner’s Manual WPC-6000 Troubleshooting chart Symptom Possible Cause(s) Corrective Action High water level in con- 1. Remove blockage from drain densate tank hose Water leakage 2. Remove any object stuc undeer- neath of the black panel nuder the water tank 1.
  • Page 12 Technical Advice and Recommendations, Disclaimer. Notwithstanding any past practice or dealings or trade custom, sales shall not include the furnishing of technical advice or assistance or system design. Weltem as- sumes no obligations or liability on account of any unauthorized recommendations, opinions or advice as to the choice, installation or use of products.

Table of Contents