Maytag Amana MVM97 Series Installation Instructions Manual page 50

Modulating gas furnace, fsp category iv direct or non direct vent air furnace

Advertisement

LED
LED Status
Off
Red
2 Flashes
Communications
LED
Rapid Flashing •   Normal network traffic
On Solid
Green
Receive
LED
S
T
YSTEM
ROUBLESHOOTING
NOTE: Refer to the instructions accompanying the ComfortNet
compatible outdoor AC/HP unit for troubleshooting information.
Refer to the Troubleshooting Codes for a listing of possible
furnace error codes, possible causes and corrective actions.
F
R
S
AULT
ECALL
EQUENCE
Only allowed in standby mode while display is
showing ON.
Hold fault recall push-button for 2-5 seconds (until
display is blank) and then release.
Display will then be blank for 2 seconds before
displaying faults stored in history.
All faults are displayed one time, from most recent
to least recent.
A Maximum of 3 consecutive faults of the same
type will be logged.
Each error is displayed for 2 seconds, with a blank
screen for 1 second in between.
When all errors have been displayed, the display
returns to ON.
F
C
S
:
AULT
LEAR
EQUENCE
Only allowed in standby mode, while display is
showing ON.
Hold fault recall push-button for 5-10 seconds
(until display starts flashing "—") and then release.
All faults in the history will have been cleared,
and display returns to ON.
If you hold the button for longer than 10 seconds,
the display will return to ON and the faults will
not be cleared.
Indication
•   Normal condition
•   None
•   Out-of-box reset
•   Control power up
•   Learn button depressed
•   Control is "talking" on
network as expected
•   Data 1/ Data 2 miss-
•   Data 1 and data 2 wires reversed
wire
at furnace, thermostat or
communicating compatible
outdoor AC/HP
•   Short between data 1 and
data 2 wires.
•   Short between data 1 or
data 2 wires and R
(24VAC) or C (24VAC
common).
Possible Causes
Corrective Action(s)
•   None
•   None
•   None
•  Check communications
wiring (data 1/ data 2
wires).
•  Check wire connections at
terminal block
•  Check data 1/ data 2
voltages.
N
S
ORMAL
EQUENCE OF
P
U
OWER
P
The normal power up sequence is as follows:
115 VAC power applied to furnace.
Integrated control module performs internal checks.
Integrated control module monitors safety circuits
continuously.
Furnace awaits call from thermostat. Dual 7-segment
LED's display O while awaiting call from thermostat.
H
M
EATING
ODE
The normal operational sequence in heating mode is as fol-
lows:
Thermostat contacts close, initiating a call for heat.
Integrated control module performs safety circuit
checks.
Induced draft blower is energized on high speed for a
15-second prepurge.
Induced draft blower steps to low speed following
prepurge. Low stage pressure switch contacts are
closed.
Igniter warm up begins upon step to low speed and
presence of closed low stage pressure switch contacts.
Gas valve opens at end of igniter warm up period,
delivering gas to burners and establishing flame.
Integrated control module monitors flame presence.
Gas valve will remain open only if flame is detected.
The percentage of heating demand is sent from the
furnace control board to determine what RPM the
draft inducer should run at. A higher percentage
demand will drive the inducer RPM higher. This will
cause the gas valve to modulate higher. The burner
will modulate based on the inducer speed
50
Notes & Cautions
•   None
•   None
•   None
•  Turn power OFF prior to
repair.
•   Verify wires at terminal
blocks are securely twisted
together prior to inserting
into terminal block.
•  Verify data 1 and data
voltages as described above
O
PERATION