Latched special
Step 1
Press and hold torch trigger
Shielding gas is expelled (gas pre-flows)
Wire feed motor runs at "creep speed".
Arc ignites after the wire electrode makes contact with the workpiece, welding current is flowing (start
program P
START
Step 2
Release torch trigger
Slope to main program P
The slope on main program P
latest when the torch trigger is released.
1)
Tapping
can be used to change over to the reduced main program P
Repeated tapping will switch back to the main program P
Step 3
Press and hold torch trigger
Slope to end program P
Step 4
Release torch trigger
WF motor stops.
Arc is extinguished after the preselected wire burn-back time expires.
Gas post-flow time elapses.
1)
Prevent tapping (brief press and release within 0.3 seconds)
If the welding current is to be prevented from switching over to the reduced main program P
tapping, the parameter value for WF3 needs to be set to 100% (P
099-00L100-EW501
4.7.2019
)
.
A
is given at the earliest after the set time t
A
.
END
Figure 6-9
.
A
= P
A
Welding procedure
MIG/MAG welding
elapses and at the
START
.
B
) in the program sequence.
B
by
B
61