Brine pump (GP2, 24-30 kW)
1 Close the brine system
shut-off valves outside the
heat pump for the relevant
cooling module.
2 Remove the front cover on
the cooling module by un-
screwing the two screws at
the top edge of the cover.
3 Draining the brine system
in the cooling module.
4 Remove the electric switch
on the circulation pump.
5 Remove the electric switch
for the control cable for the
circulation pump.
6 Disconnect and remove the
circulation pump.