ELLIPSE JAR
1. Wash, rinse, sanitize, and dry container prior to initial use and whenever
it will not be used again within a period of 1 hour.
2. Wash and rinse container after each use.
3. Clean and sanitize motor base prior to initial use and after each use.
4. Washing solutions based on non-sudsing detergents and chlorine-based
sanitizing solutions having a minimum chlorine concentration of 100 PPM
are recommended.
The following washing, rinsing, and sanitizing solutions, or their equivalents,
may be used.
SOLUTION
PRODUCT
Washing
International Products
Corporation LF2100 Liquid
Low-Foam Cleaner
Rinsing
Plain Water
Sanitizing
Clorox
®
Regular Bleach
(8.25% hypochlorite
concentration)
In repetitive batch-processing applications, frequent cleaning of the
container will prolong the life of the blade assembly. In no case should
actual running time between cleanings exceed ½ hour.
Do not use container to store processed foods or beverages.
TO WASH AND RINSE CONTAINER:
1.
REMOVE CONTAINER FROM MOTOR BASE. Remove Ellipse dasher
system (lid and dasher). Rinse container interior and lid under running
water. Add washing solution to container. Scrub and flush out the
container interior to dislodge and remove as much food residue as
possible. Empty container.
2.
Wipe down exterior of container with a soft cloth or sponge dampened
with washing solution. Fill container ¼ full with fresh washing solution,
cover (with lid only), place on motor base and run on the highest speed
for two (2) minutes. Empty container.
3.
Repeat step (2) using clean rinse water in place of washing solution.
DILUTION IN WATER
TEMPERATURE
1%–2%: 1¼ – 2¾ ounce/gallon (lower
dilution of 1% for normal cleaning and
up to 2% for more stubborn soils)
Warm 95˚F (35˚C)
2 teaspoons/gallon (alternately a bleach
with 5.25% hypochlorite concentration
can be used at dilution of 3 teaspoons/
gallon)
14
NOTE: IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING, TEMPERATURE OF
WASHING SOLUTION AND RINSE WATER MUST NOT EXCEED 115˚F (46˚C), AND
QUANTITY USED MUST NOT EXCEED ¼ CONTAINER FULL.
TO SANITIZE AND DRY CONTAINER:
1.
Wipe down exterior of container with a soft cloth or sponge dampened
with sanitizing solution.
2.
Fill container with sanitizing solution, cover, place on motor base, and run
on high speed for two (2) minutes. Empty container. Dislodge any residual
moisture from blade assembly by placing empty container on motor base
and running on the highest speed for two (2) seconds.
Room
3.
Sanitize lid and lid insert by immersing in sanitizing solution for two
temperature
(2) minutes.
4.
Do not rinse container, lid, or lid insert after sanitizing is completed.
Allow parts to air-dry.
TO CLEAN AND SANITIZE MOTOR BASE:
1.
UNPLUG POWER CORD. Wipe down exterior surfaces of motor base with
soft cloths or sponges dampened with washing solution, rinse water, and
sanitizing solution. Prevent liquid from running into motor base by wringing
all excess moisture from cloths or sponges before using them.
DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, RINSE
WATER, OR SANITIZING SOLUTION.
2.
Allow motor base to air-dry before using.
Any other servicing should be performed by an authorized service
representative.