Supermicro SuperServer SYS-621H-TN12R User Manual page 98

Hide thumbs Also See for SuperServer SYS-621H-TN12R:
Table of Contents

Advertisement

This table identifies the NVMe Port Resources in the X13 Hyper servers. Enable VMD on
the NVMe drive's corresponding hardware stack according to the VMD BIOS Settings table.
Intel VMD BIOS Settings for X13 Hyper Systems
Model
CPU1
VMD Config for PCH ports:
SYS-121H-TNR
PCH Root Port 8
8 NVMe (0-7)
PCH Root Port 9
12 NVMe (0-11)
8 SAS/SATA +
VMD Config for IOU 3:
4 NVMe (8-11)
8 SATA + 4 NVMe (8-11)
Socket 0 IOU3 port E
Socket 0 IOU3 port G
8 NVMe (0-7) +
4 SAS/SATA
VMD Config for IOU 4:
8 NVMe (0-7) + 4 SATA
Socket 0 IOU4 port A
Socket 0 IOU4 port C
VMD Config for PCH ports:
PCH Root Port 8
PCH Root Port 9
SYS-621H-TN12R
VMD Config for IOU 3:
Socket 0 IOU3 port E
12 NVMe (0-11)
Socket 0 IOU3 port G
8 SAS/SATA +
4 NVMe (8-11)
8 SATA + 4 NVMe (8-11)
VMD Config for IOU 4:
Socket 0 IOU4 port A
Socket 0 IOU4 port C
Socket 0 IOU4 port E
Socket 0 IOU4 port G
SYS-621H-TN12R
VMD Config for PCH ports:
PCH Root Port 8
2 Rear NVMe (12-13)
4 Rear NVMe (12-15)
PCH Root Port 9
VMD Config for PCH ports:
PCH Root Port 8
PCH Root Port 9
SYS-221H-TN24R
VMD Config for IOU 1:
Socket 0 IOU1 port A
24 NVMe (0-23)
Socket 0 IOU1 port C
16 NVMe (8-23) +
Socket 0 IOU1 port E
8 SAS/SATA
Socket 0 IOU1 port G
16 NVMe (8-23) +
8 SATA
VMD Config for IOU 3:
16 SAS/SATA +
Socket 0 IOU3 port E
8 NVMe (16-23)
Socket 0 IOU3 port G
VMD Config for IOU 4:
Socket 0 IOU4 port A
Socket 0 IOU4 port C
Socket 0 IOU4 port E
Socket 0 IOU4 port G
Chapter 6: Optional Components
NVMe Slots CPU2
VMD Config for IOU 0:
Socket 1 IOU0 port A
M.2 A,B
Socket 1 IOU0 port C
Socket 1 IOU0 port E
Socket 1 IOU0 port G
VMD Config for IOU 3:
NVMe 0,1.
Socket 1 IOU3 port E
Socket 1 IOU3 port G
VMD Config for IOU 4:
NVMe 2, 3
Socket 1 IOU4 port E
Socket 1 IOU4 port G
VMD Config for IOU 3:
M.2 A,B
Socket 1 IOU3 port E
Socket 1 IOU3 port G
VMD Config for IOU 4:
Socket 1 IOU4 port A
NVMe 0,1
Socket 1 IOU4 port C
Socket 1 IOU4 port E
Socket 1 IOU4 port G
NVMe 2,3,4,5
VMD Config for IOU 0:
Socket 1 IOU0 port A
M.2 A,B
Socket 1 IOU0 port C
Socket 1 IOU0 port E
Socket 1 IOU0 port G
VMD Config for IOU 0:
Socket 1 IOU0 port A
M.2 A,B
Socket 1 IOU0 port C
Socket 1 IOU0 port E
Socket 1 IOU0 port G
VMD Config for IOU 2:
Socket 1 IOU2 port A
NVMe 0,1,2,3
Socket 1 IOU2 port C
Socket 1 IOU2 port E
Socket 1 IOU2 port G
VMD Config for IOU 3:
NVMe 4,5.
Socket 1 IOU3 port E
Socket 1 IOU3 port G
VMD Config for IOU 4:
Socket 1 IOU4 port A
NVMe 6,7,8,9
Socket 1 IOU4 port C
Socket 1 IOU4 port E
Socket 1 IOU4 port G
98
NVMe Slots
NVMe 4,5,6,7
NVMe 8,9
NVMe 10,11
NVMe 6,7
NVMe
8,9,10,11
NVMe
12,13,14,15
NVMe
10,11,12,13
NVMe
14,15,16,17
NVMe 18,19
NVMe
20,21,22,23

Advertisement

Table of Contents
loading

Table of Contents