Raymarine Remote Keypad User Manual
Raymarine Remote Keypad User Manual

Raymarine Remote Keypad User Manual

Raymarine remote keypad navigation aids: user guide

Advertisement

Quick Links

SeaTalk
Remote
Keypad
Owner's
Handbook
Document number: 81073_5
Date: 1February 2003

Advertisement

Table of Contents
loading

Summary of Contents for Raymarine Remote Keypad

  • Page 1: Remote Keypad

    SeaTalk Remote Keypad Owner’s Handbook Document number: 81073_5 Date: 1February 2003...
  • Page 2 © Copyright Raymarine Limited 2003...
  • Page 3: Table Of Contents

    SeaTalk Remote Keypad Owner’s Handbook Contents Package Contents ... iii Chapter 1: Operation ... 1 1.1 Introduction ... 1 1.2 Basic operation ... 3 1.3 General information ... 4 Chapter 2: Maintenance & Fault Finding ... 5 2.1 Maintenance ... 5 2.2 Fault finding ...
  • Page 4 Chapter 4: Setup ... 13 2.1 Introduction to instrument grouping ... 13 2.2 Grouping standard instruments ... 13 2.2 Grouping ST80 MaxiView instruments ... 16 Chapter 5: Specification ... 19 SeaTalk Remote Keypad Owner’s Handbook...
  • Page 5: Package Contents

    SeaTalk Remote Keypad Owner’s Handbook Package Contents Remote keypad Thumb nuts (2) Fixing studs (2) Sun cover 5. SeaTalk cable 6. Installation template. 7. Owner’s Handbook (this book) 8. Quick Reference Guide D4545-3...
  • Page 6 SeaTalk Remote Keypad Owner’s Handbook...
  • Page 7: Chapter 1: Operation

    Chapter 1: Operation Chapter 1: Operation 1.1 Introduction The SeaTalk Remote Keypad enables you to remotely operate the following instruments on a SeaTalk system: • Standard (110 mm x 110 mm) ST60 instruments. • Standard and MaxiView ST80 instruments. The Remote Keypad has: •...
  • Page 8 Port steering station Flybridge and cabin steering stations on a power vessel Examples of typical uses for instrument groups SeaTalk Remote Keypad Owner’s Handbook Port and starboard steering stations on a catamaran Starboard steering station SeaTalk link Cabin steering station...
  • Page 9: Emc Conformance

    As each instrument is selected, it displays a remote indication, during which time you can control it from the Remote Keypad. The manner in which the remote indication is displayed depends on the type of instrument: •...
  • Page 10: General Information

    ST60 Typical remote indications 1.3 General information • The Remote Keypad beeps when a key is pressed. • The Remote Keypad is permanently illuminated to facilitate operation in all lighting conditions. The level of brightness is determined by the system illumination setting.
  • Page 11: Chapter 2: Maintenance & Fault Finding

    All Raymarine products are subjected to a comprehensive test procedure prior to packing and shipping. In the unlikely event that a fault does occur with your Remote Keypad, use the following check list to help identify and rectify the problem.
  • Page 12 All instruments operate at the same time • Instruments are not grouped. Refer to Chapter 4, Setup chapter for grouping details. Instruments cannot be remotely controlled • Not in a keypad group. Refer to Chapter 4, Setup chapter for grouping details. SeaTalk Remote Keypad Owner’s Handbook...
  • Page 13: Chapter 3 Installation

    • Raymarine specified cables should be used at all times. Cutting and rejoining these cables can compromise EMC performance and so should be avoided unless doing so is detailed in the installation...
  • Page 14: Suppression Ferrites

    If your Raymarine equipment is going to be connected to other equipment using a cable not supplied by Raymarine, a suppression ferrite MUST always be fitted to the cable close to the Raymarine unit. Tools • 5 mm twist drill •...
  • Page 15: Procedure

    Chapter 3: Installation 3.2 Procedure Install your SeaTalk Remote Keypad as follows: 1. Apply the fitting template (supplied near the rear of this handbook) to the intended location, using adhesive tape if necessary. Mark the centres for the fixing stud clearance holes (2) and the aperture (3) for the rear of the keypad.
  • Page 16: Connecting To Seatalk

    Tighten the thumb nuts BY HAND, until the keypad is secure. Do NOT use a wrench to tighten the nuts. Connecting to SeaTalk Connect your SeaTalk Remote Keypad to SeaTalk by plugging the supplied SeaTalk cable into a convenient 3-Way SeaTalk connector block.
  • Page 17: Check Before Going To Sea

    Chapter 3: Installation Masterview Autopilot connections • If you require extension cables, please refer to the display head installation chapter for a list of options. 3.3 Check before going to sea EMC conformance • Always check the installation before going to sea to make sure that it is not affected by radio transmissions, engine starting etc.
  • Page 18: Seatalk Remote Keypad Owner's Handbook

    SeaTalk Remote Keypad Owner’s Handbook...
  • Page 19: Chapter 4: Setup

    MaxiView instrument groups: • Each group can have up to eight instruments. • Each group must have at least one Remote Keypad grouped to it. • Each Remote Keypad can only be grouped with one ST80 MaxiView and one standard instrument group.
  • Page 20 (toggle action) Note: In group setup mode, all standard instruments are selectable. SeaTalk Remote Keypad Owner’s Handbook Typical ST80 digital Typical ST60 analogue key to select a instrument to be the first in the...
  • Page 21 Typical ST60 digital Group setup indications - allocating keypad (c) At the Remote Keypad, press any one of the keys dedicated to the standard instruments, to assign the Remote Keypad to the selected instrument group. 7. If you are creating more than one group, repeat the procedures described in steps 2 to 6.
  • Page 22: Grouping St80 Maxiview Instruments

    4.3 Grouping ST80 MaxiView instruments To define a group of ST80 MaxiView instruments: 1. At any Remote Keypad, press and hold the upper keys for 4 seconds. All the ST80 MaxiView instruments enter group setup mode. On one of the instruments, the display will change to reverse video and the cursor will flash.
  • Page 23 Chapter 4: Setup 6. Assign a Remote Keypad to the required group as follows: (a) Use the group. (b) Press the message PRESS A KEY ON THE KEYPAD FOR THIS GROUP is displayed. (c) At the Remote Keypad, press either the assign the Remote Keypad to the selected instrument group.
  • Page 24 SeaTalk Remote Keypad Owner’s Handbook...
  • Page 25: Chapter 5: Specification

    Chapter 5: Specification Chapter 5: Specification Dimensions: Power supply: Current consumption: Operating temperature: Buzzer: 110 mm x 68 mm x 17 mm (4.33 x 2.67 x 0.66 in) 10 V to 16 V dc 90 mA to 190 mA (illumination full on) -10°...
  • Page 27 Datum Line for Instrument & Keypad alignment SeaTalk Remote Keypad Fitting Template Drill 5mm ( ") Machine 45mm (1 ") Drill 5mm ( ") D2558-2...
  • Page 28 SeaTalk Remote Keypad Owner’s Handbook...

Table of Contents