[C] Rapid Refrigeration; [D] Defrost; [E] Shut Down; Maintenance And Cleaning Instructions - Hoshizaki RTC-120SNA-ML Instruction Manual

Undercounter refrigerator/freezer
Table of Contents

Advertisement

ENGLISH
Note: The above temperature range may not be
available when the ambient temperature
exceeds 30°C.
Set Point Button
Temperature
Display Window
Fig. 10
4) The displayed cabinet temperature is adjusted
to be almost equal to the temperature at the
center of the cabinet without foods. But it can be
different from the actual temperature depending
on arrangement of stored foods, frequency of door
opening or measuring points.

[c] RAPID REFRIGERATION

To refrigerate stored foods rapidly, choose the
rapid refrigeration mode. The Interior fan motor will
operate continuously to accelerate refrigeration.
1) Press and hold the temperature control button
(down) for 5 seconds to operate the Interior fan
motor continuously. The decimal point on the
temperature display window will disappear during
the rapid refrigeration.
2) To resume normal operation, press and hold the
temperature control button (down) button for 5
seconds. The decimal point will reappear on the
temperature display window.
Fig. 11
Temperature
Control Button
250V-10A
Decimal Point

[d] DEFROST

The refrigerator/freezer automatically defrosts the
evaporator every 6 hours. The temperature display
window shows "dF" during defrost cycle.
To start a manual defrost cycle, hold down the two
temperature control buttons at the same time for a
while. The next defrost cycle will begin in 6 hours.

[e] SHUT DOWN

1) Before shutting down the unit, move the stored
foods into another refrigerator/freezer.
2) Unplug the unit or disconnect the main power
supply.
3) When preparing the unit for long storage, clean
the cabinet interior and door gaskets, dry them
thoroughly and store the unit in a dry place.
III. MAINTENANCE AND CLEANING
INSTRUCTIONS
IMPORTANT
1. B e f o r e c a r r y i n g o u t a n y c l e a n i n g o r
maintenance operations, unplug the unit.
2. D o n o t t o u c h o r w e t t h e m a c h i n e
compartment parts. This could result in
failure or breakdown.
3. To prevent possible damage, do not clean
the plastic parts with water above 40°C or in
a dishwasher.

1. INTERIOR, EXTERIOR, SHELF

* Clean the interior and exterior at least once a
week for sanitary use. The unit can be moved by
unlocking the casters [caster models].
* Clean off the interior and exterior with a soft cloth
soaked in cold or warm water containing the proper
amount of neutral cleaner and wrung dry. Do not
use a water jet to clean the machine compartment.
* Chemical agents other than neutral cleaner might
cause damage to the interior and exterior surfaces.
* Any remaining detergent will damage metal or
plastic surfaces. Use a soft cloth dampened with
warm water to wipe it off.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtc-180sna-mlFtc-120sna-mlFtc-180sna-ml

Table of Contents