Technical Data - Rangemaster 110 Dual Fuel User Manual

Installation & service instructions
Table of Contents

Advertisement

Technical Data

This cooker is category II
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with
the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp 1/2 at rear right-hand side
Ratings
Hotplate
Right hand High burner
Large Burner
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorifi c Value
Ovens
Energy efficiency class :
on a scale of A (more effi cient) to G (less effi cient)
Energy consumption based on standard load
Usable volume (litres)
Size
Time to cook standard load
Surface area of the grid
Grill
Warmer
Maximum total electrical load at 230V 7.2kW (approximate total including oven lights, oven fan etc.)
2H3+
20mbar
29mbar
37mbar
Overall height
minimum 893mm
Overall width
1100mm See 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
650mm
Natural Gas
3.0kW
3.0kW
1.7kW
1.0kW
2.3kW
160W
Electric
220 - 240V 50Hz
maximum 920mm
Electric
220 - 240V 50Hz
Injector
128
134
109
75
Conventional
Oven
2.2 kW
A
0.99kWh
67
Large
40 minutes
1400cm
34
L.P. Gas
3.0kW (210g/h)
3.0kW (210g/h)
1.7kW (119g/h)
1.0kW (70g/h)
Forced air convection
Browning
Element
1.15kW
2
Injector
87
87
68
51
2,5 kW
A
0.85kWh
67
Large
38 minutes
2
1400cm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents