5) Release the pushbutton to restore to default and then press again.
Pressing a disabled push-button, the "chime excluded" LED "H" will flash to
indicate this operation mode.
Deleting all settings.
Programming phase:
This procedure is advised when you want to change the ID of an interphone/
monitor previously programmed and you do not want keep the operation
programming of the appliance.
1) Press and hold the RESET pushbutton "G" present below the monitor
(see Fig. 4).
2) Press and hold the self-start pushbutton
RESET pushbutton "G".
3) Release the RESET pushbutton "G", keeping the self-start pushbutton
"E" pressed.
4) After 2 seconds the monitor emits a continuous tone for two seconds.
5) Release the self-start pushbutton "E".
6) During the continuous tone, press the lock release pushbutton "D".
If the deletion procedure is successful, when the lock release tab is pressed
once more the interphone emits a triple "Beep".

OPERATION

Calls from an entrance panel, intercommunicating calls and door calls are
differentiated by means of different tones.
Door calls.
Calls from entrance panels do not follow the pressed pushbutton but are
generated inside the monitor. The call interval is 1 s of ringtone and 2 s of
pause repeated twice (default value set on panel). To answer, raise the
handset. If the handset is already raised during the call, replace and raise it
again. The call answer time (30 s) and the conversation time (2 minutes by
default) are set in the panel parameters. When the conversation time has
elapsed, the user can continue without replacing the handset if a new call
is made within 10 s from the same panel.
Intercommunicating call.
Lift the monitor handset and press the intercommunicating button, if pro-
grammed, for the interphone/monitor to be called. On the handset of the
monitor calling, a call tone will ring (if the call is enabled) or an engaged
tone (if not enabled). On the called monitor the ringtone starts sequentially
at intervals of 1 s ringing and 4 s pause. The maximum duration of the call is
30 s (6 cycles). To answer the call, simply raise the handset; the maximum
duration of the conversation is 5 minutes. When the conversation time has
elapsed, the user can continue without replacing the handset if a new call
is made within 10 s. Calls from the panel have priority over intercommuni-
cating calls.
Denied calls.
The variator located below the monitor (Fig. 4) enables modification to the
call volume or to mute the signal. Call mute is indicated by permanent illumi-
nation of the red LED. If calls are made to the monitor when the call mute is
enabled, they are denied. A denied call causes the red Led to briefly switch
off according to the number of times calls are denied (maximum 4 denied
calls). The signal is repeated every 10 s (approx.). Deletion of denied calls is
by: reenabling the ringtone, resetting the monitor or a system power failure.
On the panel, a denied call is indicated by means of a dissuasion tone (a se-
ries of "Beeps" at 100ms intervals with a pause of 100ms for a total of 5 se-
conds). The message "Do not disturb" also appears on panels with display.
Lock Button
The lock button of each device works in the following manner.
- Device with handset at rest
which it has spoken or from which it has been called.
- Device with handset raised but not engaged in a conversation
to switchboard if the Switchboard flag is YES. Otherwise it goes back to
the first case.
- Device with handset raised and engaged in an internal conversation
as in the first case.
- Device with handset raised and engaged in an external conversation or
called from entrance panel lock
EN
"E" together with the
lock to the last entrance panel with
to the entrance panel being
spoken with or from which it has been called.
In practice a lock is always activated except when the handset is raised
and you immediately press the lock button. This can also be taken to the
standard case if the system has no porter switchboard and the Switchboard
flag is set on NO.
INSTALLATION RULES.
Installation should be carried out observing current installation regulations
for electrical systems in the Country where the products are installed.
CONFORMITY.
EMC directive
Standards EN 61000-6-1, EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE 2002/96
(WEEE)
In order to avoid damage to the environment and human health as
well as any administrative sanctions, any appliance marked with
this symbol must be disposed of separately from municipal waste, that is it
must be reconsigned to the dealer upon purchase of a new one. Applianc-
es marked with the crossed out wheelie bin symbol must be collected in
accordance with the instructions issued by the local authorities responsible
for waste disposal.
call
9