Inductance Selection - Miller CP-302 Owner's Manual

Hide thumbs Also See for CP-302:
Table of Contents

Advertisement

5-3. Inductance Selection

Weld Bead Using The Tap Stabilizer
Connection With 17 Volts, 100 Amps
Tools Needed
:
3/8, 7/16 in.
3/8 in.
OM-259 Page 14
.
A complete Parts List is available at www.MillerWelds.com
2
5
4
6
Weld Bead Using The End Stabilizer
Connection With 17 Volts, 100 Amps
!
Lockout/tagging procedures con-
sist of padlocking line disconnect
switch in open position, removing
fuses from fuse box, or shutting off
and red-tagging circuit breaker or
other disconnecting device.
1
Tapped stabilizer Z is factory
connected to the stabilizer tap
which
applications.
Stabilizer Z controls the inductance
applied to the weld current. To in-
crease inductance and wet out the
weld puddle, connect to stabilizer Z
ending.
To change inductance proceed as
follows:
2
3
4
5
To increase inductance, connect
lead 26 to stabilizer ending and
secure.
Reinstall side panel.
1
6
Use the tap Stabilizer connection to
obtain arc type and weld bead suit-
able for some mild steel applica-
tions.
7
Use the end Stabilizer connection
to reduce weld bead crowning, and
spread the weld puddle.
3
7
Disconnect and lockout/tag-
out input power before re-
moving side panel.
Stabilizer Z
suits
most
GMAW
Lead 25
Stabilizer Z Tap
Stabilizer Z Ending
Lead 26
Typical Weld Bead Using The
Tap Stabilizer Connection
Typical Weld Bead Using The
End High Stabilizer
Connection
ST-801 379-B

Advertisement

Table of Contents
loading

Table of Contents