IMPORTANT
We recommend an additional standard 120 V/15 A NEMA 5-15 outlet for
service tools, such as a laptop computer or vacuum that may be used when
servicing or configuring the machine.
Use only dedicated and properly grounded outlets for the main unit and
imagePRESS Server Controller. It is also strongly suggested to use
dedicated and properly grounded outlets for each optional accessory. Do
not use extension cords. The ground connection serves to provide the
internal electronics with a reference voltage. Faulty or poor ground sources
will cause this reference voltage to fall into a range that no longer serves
as a reliable reference voltage. The internal logic and programming of the
imagePRESS machines will not perform reliably if there is an insufficient
difference between the internal operating signal voltages and the poor
ground reference signal. A qualified electrician can measure and provide
the ground source that the imagePRESS machines or any computer
controlled office equipment requires.
Before installation, confirm that all necessary receptacles are available.
Phase converters and step down transformers are not supported.
Figure 2 – Power and Plug Requirements (Finisher-W1 PRO
imagePRESS Lite C170 Series Service Guide
Revision 11
Configuration)
imagePRESS Lite C170 Series Service Guide
March 2022