Siemens SICHARGE UC Operating Instructions Manual page 57

Table of Contents

Advertisement

Connecting the PE conductor
First, connect the PE conductor of the power supply cable to the grounding connector:
1. Remove the sheath of the power supply cable to approximately 8 cm in length.
2. Select a wire end ferrule for the appropriate conductor cross-section.
3. Strip the insulation from the end of the conductor so that the remaining insulation
extends up to the ferrule.
4. Properly attach the wire end ferrule to the conductor end.
5. Insert the wire end ferrule into the terminal strip of the ground connection.
6. Check the connection of the PE conductor to the PE terminal.
Connecting cable L1, N
To connect a conductor, follow these steps:
1. Remove the sheath of the power supply cable to a length of approx. 5 cm.
2. Select a wire end ferrule for the appropriate conductor cross-section.
3. Strip the insulation from the end of the conductor so that the remaining insulation
extends up to the ferrule.
4. Properly attach the wire end ferrule to the conductor end.
5. Insert the wire end ferrule into the terminal strip of the respective conductor.
6. Check the connection of the conductor to the terminal.
Attaching the power supply cable
Secure the power supply cable after the connection to the cable duct.
Connection of additional SICHARGE UC Dispenser
The mains connection is looped through to connect additional SICHARGE UC Dispenser to the
same SICHARGE UC charging station. This is shown as item
connection" figure. To do this, follow the above sequence to connect the power supply cable.
SICHARGE UC Dispenser
Operating Instructions, 06/2023, A5E50235695-AE
6.2 Connecting the power supply cable
in the "Power supply cable
Connecting
57

Advertisement

Table of Contents
loading

Table of Contents