Vertical Oscillation And Vertical Ratio Data; Tips For Missing Running Dynamics Data; Using The Varia Camera Controls; Inreach Remote - Garmin FENIX 6 Series Owner's Manual

Hide thumbs Also See for FENIX 6 Series:
Table of Contents

Advertisement

Vertical Oscillation and Vertical Ratio Data

The data ranges for vertical oscillation and vertical ratio are slightly different depending on the sensor and
whether it is positioned at the chest (HRM-Pro series, HRM-Run
(Running Dynamics Pod accessory).
Percentile in
Color Zone
Zone
Purple >95
70–95
Blue
30–69
Green
Orange 5–29
<5
Red

Tips for Missing Running Dynamics Data

If running dynamics data does not appear, you can try these tips.
• Make sure you have a running dynamics accessory, such as the HRM-Pro accessory.
Accessories with running dynamics have
• Pair the running dynamics accessory with your watch again, according to the instructions.
• If you are using the HRM-Pro accessory, pair it with your watch using ANT+ technology, rather than Bluetooth
technology.
• If the running dynamics data display shows only zeros, make sure the accessory is worn right-side up.
NOTE: Ground contact time and balance appears only while running. It is not calculated while walking.

Using the Varia Camera Controls

Some jurisdictions may prohibit or regulate the recording of video, audio, or photographs, or may require that
all parties have knowledge of the recording and provide consent. It is your responsibility to know and follow all
laws, regulations, and any other restrictions in jurisdictions where you plan to use this device.
Before you can use the Varia camera controls, you must pair the accessory with your watch
Wireless Sensors,
page 91).
1 Add the RCT Camera widget to your watch
2 From the RCT Camera widget, select an option:
• Select to view the camera settings.
• Select
to take a photo.
• Select
to save a clip.

inReach Remote

The inReach remote function allows you to control your inReach device using your fēnix device. Go to
.garmin.com
to purchase a compatible inReach device.
94
Vertical Oscillation
Vertical Oscillation
Range at Chest
Range at Waist
<6.4 cm
<6.8 cm
6.4–8.1 cm
6.8–8.9 cm
8.2–9.7 cm
9.0–10.9 cm
9.8–11.5 cm
11.0–13.0 cm
>11.5 cm
>13.0 cm
on the front of the module.
NOTICE
(Widgets,
page 79).
, or HRM-Tri accessories) or at the waist
Vertical Ratio at
Chest
<6.1%
6.1–7.4%
7.5–8.6%
8.7–10.1%
>10.1%
Vertical Ratio at
Waist
<6.5%
6.5–8.3%
8.4–10.0%
10.1–11.9%
>11.9%
(Pairing Your
buy
Wireless Sensors

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FENIX 6 Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF