Riello 3438964 Installation, Use And Maintenance Instructions page 36

Heavy oil burners
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
TECHNICAL DATA
2.
TYPE
Thermal power - Output
Fuel
Pump
2.1
ELECTRICAL DATA
CODE
Electrical supply
Motor IE3
Ignition transformer
Heaters
Absorbed electrical power
MODELS AVAILABLE
Model
PRESS 300 P/N
2915844
626 - 3420 kW
Oil with max. viscosity at 50° C
for oil up to
470 kg/h at 25 bar
3N ~ 50 Hz 400 V with neutral
3 ~ 50 Hz 230 V without neutral
rpm
kW
V
A
19,6 kW
kW max
Code
Electrical supply
3438964
230V - 400V
3438965
3438968
400V
3438969
468 M1
55 - 300 kg/h (see tables below)
3438964 - 3438965
2930
9.2
230/400
28.6/16.5
Prim.: 2A - Sec.: 2 x 6.5 kV - 35 mA
30,2
2
GB
2
50 mm
/s
(7° E)
2
500 mm
/s (65° E)with kit
3438968 - 3438969
2930
9.2
400/690
16.5/9.6
30,2
Motor
Direct starting
Direct starting
Star-delta starting
Star-delta starting

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

468 m1Press 300 t/n343896534389683438969

Table of Contents