Kodak ThermoFlex Wide II Site Preparation Manual page 9

Output device
Table of Contents

Advertisement

Equipment Overview
Cables
Output device main power
Drum vacuum drive power
Workstation power
Chiller power
Debris removal cabinet power
Telephone line
a. The tolerances for input voltages are +6%, –10%. The specification for the frequency is 50/60 Hz
Branch circuits should have time delay type circuit breakers to avoid nuisance tripping caused by inrush
currents. For details, refer to Electrical on page 13.
Table 3: Cables and Interconnects—Europe, Australia and S.E. Asia
Supplied by Kodak
Attached 4.5 m (14.7 ft.) power cord
with L6-30P plug
Labeled terminals for hookup of AC
mains input cable (3-phase plus
ground). Pilot hole for appropriate
conduit fitting.
IEC320, type C14 appliance inlet
2.5 m (8.2 ft.) power cable with 5-
15P connector
See the UDRC Site Preparation Guide (part number 725-00089A).
Serial cable for modem
a
Required by customer
Dedicated 32A, 200-240 V circuit
with IEC309 32 A/250 V
receptacle and slow-blow circuit
breaker
Dedicated 20 A, 340-440 VAC
(±0%), 50/60 Hz, 3-phase
branch circuit with circuit breaker
protection.
Wiring, circuit breaker and panel
fittings supplied by customer in
accordance with local electrical
standards.
IEC320, type C13 connector with
8 A cord
Dedicated 8 A, 200–240 V branch
circuit
Dedicated 120 V, 15 A branch
circuit with 5-15R receptacle
Two dedicated telephone lines and
RJ-11 cables to plug into modem
(must be long enough to reach
workstation). One line is to
connect to the workflow, and the
other is to connect to Kodak
remote support.
Also requires separate AC power
source (UPS provided only with
IEC type 320 outlet receptacles).