Cables, Connectors, And Receptacles - Kodak ThermoFlex Wide II Site Preparation Manual

Output device
Table of Contents

Advertisement

4

Cables, Connectors, and Receptacles

Cables
Output device main power
Drum vacuum drive power
Workstation power
Chiller power
Debris removal cabinet power
Telephone line
a. The tolerances for input voltages are +6%, –10%. The specification for the frequency is 50/60 Hz
Branch circuits should have time delay type circuit breakers to avoid nuisance tripping caused by inrush
currents. For details, see Electrical on page 13.
Tables 2–4 list the supplied and required cables and connectors for the output
device. Table 5 lists the power/air connections. An overview of the system
connections is shown in Figure 1 on page 8.
Table 2: Cables and Interconnects—North America
Supplied by Kodak
Attached 4.5 m (14.7 ft.) power cord
with L6-30P plug
Labeled terminals for hookup of AC
mains input cable (3-phase plus
ground). Pilot hole for appropriate
conduit fitting.
Detachable 2.5 m (8.2 ft.) power
cable with 5-15P plug
2.5 m (8.2 ft.) power cable with 5-
15P connector
Refer to the UDRC Site Preparation Guide (part number 725-00089A).
Modem and serial cable. The
modem power supply can be
plugged into a UPS.
ThermoFlex Wide II Site Preparation Guide
Required by customer
Dedicated 30 A, 200-240 V
circuit (single phase) with L6-30R
receptacle. The circuit breaker
must be 30 A time-delay type.
Dedicated 20 A, 340-506 VAC
(±0%), 50/60 Hz, 3-phase branch
circuit with circuit breaker
protection.
Wiring, circuit breaker and panel
fittings supplied by customer in
accordance with local electrical
standards.
Dedicated 15 A, 120 V branch
circuit and 5-15R receptacle
5-15R receptacle and dedicated
120 V, 15 A branch circuit
Two dedicated telephone lines and
RJ-11 cables to plug into modem
(must be long enough to reach
workstation). One line is to
connect to the workflow, and the
other is to connect to Kodak
remote support.
a
±
1.5%.