Electrical; Power Quality; Special Precautions - Kodak ThermoFlex Wide II Site Preparation Manual

Output device
Table of Contents

Advertisement

Site Requirements

Electrical

Power Quality

Special Precautions

The dedicated branch circuit for the output device main power, external chiller
power, debris removal system main power, and workstation main power must be
supplied from the same AC supply panel to ensure that all branch circuits are at the
same ground potential.
Figure 4 shows the configuration of the receptacles used by the device and
peripheral equipment.
5-15R
IEC309
Figure 4: Receptacles used on ThermoFlex Wide devices
See the UDRC Site Preparation document (725-00089A) for information on UDRC
electrical connections.
If you suspect that there are problems with the power supply, a power monitor
should be installed to measure power quality. If the power supply is unreliable, a line
conditioner may be required. If power in the local area is suspect, check with the
local service
If the power quality at the customer site is outside Kodak specifications (+6%/–
10%), the customer should purchase a line conditioner for the ThermoFlex Wide II
circuit from a local supplier.
If there are concerns about power quality (blackouts or brownouts) at the customer
site, an online uninterruptible power supply (UPS) device can be purchased from a
local supplier. A UPS allows a correct, complete shutdown of the device. (A line
conditioner allows the device to function for extended periods of time when the
power conditions are outside of the ThermoFlex Wide II specifications.
Note: A UPS does not provide adequate line conditioning.
UPS specifications are available from the supplier.
The plugs on the power cord(s) of the system are intended to be the disconnect
device. Therefore, the branch circuit receptacle(s) must be installed near the
ThermoFlex Wide II and be easily accessible.
L6-20R
IEC320
13