Benchmark Alpha E-Tec Plus 28 Installation And Servicing Instruction page 25

Wall mounted, fan assisted, room sealed, gas fired, high efficiency condensing combination boiler
Table of Contents

Advertisement

Terminal end section
from CD Easy-Flue
PM length = C + (1 x 93° bend = 1.3 m) + (2 x 45° bends = 1.8 m)
Note: The equivalent horizontal flue assembly length + the equivalent plume management length (PM length) must not
exceed the maximum flue length stated for each boiler, i.e.
E-Tec boilers - the maximum equivalent flue length must not exceed 12 metres.
Min.
400 mm
C
PM length = C + (2 x 93° bend = 2.6 m) + (2 x 45° bends = 1.8 m)
Flue sealing collar
CD Easy-Flue
C
Ensure there is a slope of approximately
3° back towards the Easy-Flue
PM length = C + (4 x 93° bend = 5.2 m)
Fig. 5.13
Alpha E-Tec Plus 28, 33 and 38 - Installation
Terminal end section
from CD Easy-Flue
Note:
1. Ensure each joint is
secured with the screw
supplied.
2. Ensure there is always
a slight slope towards
the CD Easy-Flue so
that there is no part
of the pipework where
condensate will collect.
Terminal end section
from CD Easy-Flue
C
25