Regency Fireplace Products Greenfire GF900C-NG1 Owners & Installation Manual page 33

Table of Contents

Advertisement

GF900
8. Remove burner by removing 2 screws at the back of the burner in
locations shown below.
Diagram 5 - Burner Screw Locations
9. Pull off the pilot cap to expose the pilot
orifice (see right).
.
10
Unscrew the pilot orifice with the Allen key and replace
with the LPG pilot orifice in the kit and replace pilot cap
(see right).
11. Remove burner orifice with a 12mm spanner and discard. Use
another spanner to hold on to the elbow below the orifice.
919-131a
Regency GF900C-1 Gas Fireplace
Pilot Cap
Pilot Orifice
Diagram 4 - Remove Pilot Cap
12. Reinstall new burner orifice LP stamped #53 or ULPG burner
orifice stamped #53 and tighten.
13. Replace the yellow "NG" label with the red "ULPG" label.
14. Carefully pull out the control box.
NOTE: The control box is held in place with velcro.
15. Remove the heat shield from the control box by removing the 2
screws.
16. Remove the control box cover by undoing the 3 screws.
Manoeuvre through antenna.
17. Remove the jumper using pliers.
Jumper
18. Reverse steps 15-14, for both units.
19. Adjust the air shutter opening (See page 30 for Aeration
Adjust-ment).
For GF900C reverse steps 8-6 and 1.
For GF900L reverser steps 5-1.
20. Turn on gas supply and plug in power cord.
2
installation
Antenna
Control Box
Cover
Jumper Location
12/06/16
33

Advertisement

Table of Contents
loading

Table of Contents