Troubleshooting - YANGZI YZ-X5 Operating Instructions Manual

Floor
Hide thumbs Also See for YZ-X5:
Table of Contents

Advertisement

Instruction Manual

troubleshooting

Same problem
The machine is
inoperable
The brush
motor is not
working
The vacuum
motor does not
work
Little ornoflow
out
cause
The battery is dead
Battery failure
Battery wiring is loose
Replace the main
Lift the brush head off the
ground
The battery meter is locked
and not started
The brush plate motor circuit
breaker triggers the power
switch
Brush (up/down) switch
failure
Motor carbon brush wear
Water suction steak rises off
the ground
Vacuum motor fuse blown
Vacuum motor or wiring fault
Motor carbon brush wear
Drain tank filter or solution
pipe is blocked
The flow control knob is set
too low
Loosen the screw of the
control-system knob
The battery is charged
Tighten the battery wiring
fuse when it blows
lower the brush head
The battery is charged
reset the brush circuit breaker button
please contact service center
please contact service center
drops water suction steak
please contact service center
please contact service center
clean drain tank filter
0 adjust the flow control knob
lubricate the knob and tighten the
9
YZ-X5
solution
replace battery
replace the fus
screw

Advertisement

Table of Contents
loading

Table of Contents