Chapter 1 Description 1.1 Content and Purpose The following content points out potentially dangerous situations, please read these instructions carefully and take necessary precautions. The essence of this machine operating manual is to prevent injuries, and most accidents are caused at work by not heeding basic safety rules.
Page 5
●Confirming that the machine is in proper operation and safe condition, professionals or service center must work in accordance with the maintenance section of this manual. ●Even if the machine is to be dismantled and scrapped, someone should be there to observe it. Because some harmful substances (such as batteries, waste oil, etc.) have met the standards, they should be sent to a specific center for processing.
Chapter 2 Instruction 2.1 Buttons/Panels of the Machine Center control panel A Center control panel B 2.1.1 The core control keys of the machine ●Power/Voltmeter (The display device can display the current battery voltage, please charge when the voltage is lower than 21V) ●Power switch (start this switch, the device is powered on) ●Water suction button (start this button, the suction motor starts to work) ●Brushing button (start this button, the brushing motor starts to work)
Page 7
Before using the machine, open the water tank cover and pour clean water into the water tank. Pay attention to the clean water quality to prevent the waterway from being blocked. When the machine is used to clean the epoxy floor, it is necessary to replace the ordinary brush plate with the needle plate and add a cleaning pad for cleaning, which can effectively protect the ground from wear and tear.
Page 8
●By pulling the handle, put down the squeegee head; ●Open the water valve; ●Turn on the main power switch, start the brush plate switch button and the water absorption motor switch button; ●Hold the handle tightly and keep driving at a constant speed. (Ordinary paragraph) ●Turn on the speed control switch (note: the speed should not be too fast when cleaning), lightly press the travel switch to keep the machine running smoothly.
Machine storage and maintenance ●If the machine will not be used within 30 days, store the machine in a clean and dry place and disconnect the battery connector. Chapter 3 Routine Maintenance and Disassembly and Replacement of Wearing Parts 3.1 Periodic Inspection Regular maintenance and inspection Intervals(h)...
Page 10
3.2 Brush disk replacement and installation ● Park the machine on a flat ground, turn off the main power switch, and ensure that the machine is in a power-off state; Lightly step on the foot lever to keep the brush disc lifted; ●For the direction of the brush plate, hold the brush, turn it to the right, and the brush plate can be removed;...
Page 11
2. Fasten the plastic components to the squeegee cast aluminum base plate 3. Align the eyelet of the rear rubber strip with the squeegee plastic assembly to the protrusion; 4. Use the pressure strip to snap on both ends 5. Tighten the nut. 3.4 Battery Maintenance The power system of this washing machine is powered by two 12V maintenance-free lead-acid batteries in series, and the system voltage is 24V.
Page 12
●The first-generation self-propelled controller is located inside the clean water tank; the X4 second-generation self-propelled controller is located inside the handle. Rated voltage: 24V; Output current: 60A; ●During the use of the machine, when the machine does not move, you can use a multimeter to measure the positive and negative poles of the power cord of the controller to check whether there is any voltage.
3. Use the M4 Allen wrench to loosen the fixing screws of the controller and the iron plate to remove it. (Note: When installing, the positive and negative wiring cannot be wrongly connected) Disassembly and assembly of the second-generation self-propelled controller: 1.
Problem Reason Solution Battery dead Charge Battery failure Replace the battery Machine doesn’t work Battery wiring loose Tighten the battery wiring Main fuse blown better fuse The brush head is lifted off the Lower the brush head ground Brush motor Brush disc motor circuit breaker Reset brush circuit does not work...
Page 15
Machine life and operational safety must be ensured by proper and routine maintenance of the machine. The routine maintenance requirements are tabulated below. Under suitable working conditions, the maintenance interval can be changed, which must be determined by the professional responsible for the maintenance. To perform maintenance operations, the machine must be stopped (remove the start switch key), so please read the safety section of the manual carefully.
Warranty card Name Tell Postal address Bill No Purchase time Number Product model Date Replace Fault description Warranty Conditions 1. Within the day when the user purchases this product, the motor is guaranteed for one year (more than 7 days from the date of purchase, no replacement, only warranty);...
Need help?
Do you have a question about the X4 and is the answer not in the manual?
Questions and answers