Table 4-5-1: Descriptions of the
Low Voltage Disconnection / Low Voltage
When the battery voltage is lower than the value for the low‐voltage disconnection (LVD), the controller will
stop supplying power to the load. It requires the charging from the PV panel so as to increase the battery
voltage to be above the value for low‐voltage reconnection (LVR) and thus the PoE device can be recovered
as the screen in
Figure 4-5-2
Figure 4-5-2
Description
disconnection, the controller will not supply to the load so as to protect
the battery from overly discharge.
DC 23.5V (23.5~27.0V)
If the battery voltage is recovered and higher than the value for low
voltage reconnection, the low‐voltage circuit disconnection will be lifted
and the connection is restored.
Off
Log & Trap
Cut-Off
Log, Trap & Cut
Press this button to revert to previously saved values.
Press this button to take effect.
to
Press this button to reset FCV, ACV, LVD and LVR settings to default
values.
Press this button to reboot the energy system board.
appears.
Low Voltage Disconnection / Low Voltage Reconnection
Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch/Router
Disable this function.
When the battery capacity is lower than 20%, log
and SNMP trap will be sent to server.
When the battery capacity is lower than 20%, log
and SNMP trap will be sent to server, and power to
the low priority port will be shut off.