Bosch Rexroth IndraDrive HMV02 Operating Instructions Manual page 39

Table of Contents

Advertisement

DOK-INDRV*-HMV02******-IT01-EN-P
Rexroth IndraDrive Supply Units HMV02
Pin Assignment
Connec‐
Fig.5-11:
Connection Point X32
Contact Bb1
Integrate the Bb1 contact in the control circuit for the mains con‐
nection (see also Project Planning Manual of drive system; index
entry "Mains connection → Control circuits").
When Bb1 contact opens, the mains contactor must interrupt the
power supply.
Bosch Rexroth AG
Signal
Function
tion
name
9
24V_IF
Supply of circuits for control of
DC bus short circuit and mains
1
0V
contactor
2
24V
Output (24 V) for connecting in‐
put X32.3
3
Braking re‐
Switching the braking resistor
sistor
switch-on threshold
switch-on
Infeeding supply units:
threshold
Regenerative supply units:
The input is not active.
Switch-on thresholds: See tech‐
nical data, table "Data of Built-in
Braking Resistor"
4
EIN2
Connection for N/O contact to
control the mains contactor
5
EIN1
(switch-on)
The input is edge-controlled
6
AUS2
Connection for N/C contact to
control the mains contactor
7
AUS1
(switch-off)
8
ZKS
Controls the ZKS stage:
37/71
Instructions for Use
Connected to 24 V of
X32.2:
Activates fixed threshold
(independent of mains
voltage)
Not connected:
Activates variable thresh‐
old (depending on mains
voltage)
Not connected: ZKS active
Connected to 24 V: ZKS
not active

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive hmv02.1r-w0015

Table of Contents