Notes on Installation
Contact Bb1
Integrate the Bb1 contact in the control circuit for the mains con‐
nection (see also Project Planning Manual of drive system; index
entry "Mains connection → Control circuits").
When Bb1 contact opens, the mains contactor must interrupt the
power supply.
Data
Number of poles
Type
Design
Connection cable solid wire
Connection cable stranded wire
Current carrying capacity
Voltage load capacity
Minimum load of the contacts
Contact resistance at minimum
load
Number of mechanical switching
cycles
Fig.5-9:
Technical Properties
For the application prototypes of the supply units, the "WARN"
contact had been realized as N/O contact. From the following
hardware indices (HWIs) upwards, the "WARN" contact is realiz‐
ed as N/C contact:
HMV01.1E-W0030: From HWI -14 upwards
HMV01.1E-W0075: From HWI -14 upwards
HMV01.1E-W0120: From HWI -15 upwards
HMV01.1R-W0018: From HWI -17 upwards
HMV01.1R-W0045: From HWI -17 upwards
HMV01.1R-W0065: From HWI -18 upwards
Bosch Rexroth AG
Instructions for Use