Ratings And Dimensions - Bosch Rexroth IndraDrive HMV02 Operating Instructions Manual

Table of Contents

Advertisement

DOK-INDRV*-HMV02******-IT01-EN-P
Rexroth IndraDrive Supply Units HMV02
3

Ratings and Dimensions

Description
Listing according to UL standard
(UL)
Listing according to CSA standard
(UL)
UL files (UL)
Pollution degree (UL)
Ambient temperature with nominal
data (UL)
Ambient temperature with reduced
nominal data (UL)
Mass
Device height (UL)
1)
Device depth (UL)
2)
Device width (UL)
3)
Minimum distance on the top of
the device
4)
Minimum distance on the bottom
of the device
5)
Horizontal spacing on the device
Rated control voltage input (UL)
Rated power consumption control
voltage input at U
(UL)
8)
N3
Short circuit current rating (UL)
Rated input voltage, power (UL)
Tolerance rated input voltage (UL)
Input frequency (UL)
Tolerance input frequency (UL)
Rated input current (UL)
Branch
circuit
protection
(UL)
10)
Required wire size according to
EN 60204‑1
11)
Required wire size according to
UL 508 A (internal wiring); (UL)
Field wiring material (material;
conductor temperature; class)
UL Ratings and Dimensions
Symbol
Unit
T
°C
amax
T
°C
amax_red
m
kg
H
mm
T
mm
B
mm
d
mm
top
d
mm
bot
d
mm
6)
hor
U
V
7)
N3
P
W
N3
SCCR
A rms
U
V
9)
LN_nenn
%
f
Hz
LN
Hz
I
A
LN
fuse
A
mm
2
LN
A
AWG
LN
12)
Bosch Rexroth AG
HMV02.1R-W0015
UL 508 C
Canadian National Standard(s) C22.2 No. 14-10
E 134201
2
40
55
9,50
352
205
150
80
80
0
24 ± 5 %
27
42000
3 x AC 380...480
±10
50...60
± 2
23,0
50
6
AWG 10
Cu; 60/75 °C; 1
Last modification: 2011-05-11
23/71
Ratings and Dimensions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive hmv02.1r-w0015

Table of Contents