STEP
6 -
Using a spanner wrench on the bottom fitting, or, a strap wrench on the
bottom end of the casing (pump bottom), turn the parts together until the
casing just contacts the pump head.
STEP
7 -
Turn the bottom check valve or the plug in the reverse direction (counter
clockwise) so it is looser by 1/4 turn.

Cleaning the Pump Cycle Counter

Refer to Appendix F – Pump Cycle Counter

Checking Volumes Pumped Per Cycle

See page 21 for information on the AutoPump volumes pumped per cycle. Ensure that
volumes correspond with the previous experience on-site, and with the ranges indicated on
page 21. If it doesn't correspond, then one of the following may exist:
1. The AutoPump is malfunctioning. (See Chapter 7: Troubleshooting & Repair)
2. The Pump Cycle Counter may not be counting correctly. See Appendix F – Pump Cycle
Counter for troubleshooting procedures.
3. Site conditions (e.g. air pressure, discharge head) may have changed substantially.
Revision 7 - August, 2007