WALL MOUNTED HIGH EFFICIENCY GAS FIRE
IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE
Please note : Except where otherwise stated, all rights, including copyright
in the text, images and layout of this booklet is owned by Focal Point Fires
plc. You are not permitted to copy or adapt any of the content without
the prior written permission of Focal Point Fires plc.
MODELS COVERED BY THESE INSTRUCTIONS
5090 GAS FIRE
MODEL SHOWN: EKO 5090 GAS FIRE
All instructions must be handed to the user for
safekeeping.The products covered by this booklet
are protected under patent GB2275331C.
1
GB IE
Revision B - 07/16
© 2016 Focal Point Fires plc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKOFIRES EKO 5090 and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point EKOFIRES EKO 5090

  • Page 1 Please note : Except where otherwise stated, all rights, including copyright safekeeping.The products covered by this booklet in the text, images and layout of this booklet is owned by Focal Point Fires are protected under patent GB2275331C. plc. You are not permitted to copy or adapt any of the content without Revision B - 07/16 the prior written permission of Focal Point Fires plc.
  • Page 2: Table Of Contents

    • Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material. © 2016 Focal Point Fires plc.
  • Page 3: Appliance Data

    The appliance must not be positioned vertically within 60mm (2.4”) of a solid floor (i.e. wood or stone) or hearth. This dimension is measured vertically to the bottom of the appliance firebox. © 2016 Focal Point Fires plc.
  • Page 4: Ventilation

    Please dispose of all the packaging materials at your local recycling centre. 5.1 COMPONENT CHECKLIST QUANTITY DESCRIPTION Firebox and burner assembly Set of manufacturers instructions Decorative facia assembly Screw and wall plug pack Rubber grommet Fitting template © 2016 Focal Point Fires plc.
  • Page 5: Gas Supply Routes

    Focal Point Fires plc. assumes absolutely no responsibility for injuries and/or damages that load of the appliance. Measures may occur due to improper installation or handling. The appliance should not be installed should also be taken to ensure until all wet plastering and/or dry wall sanding and wall painting has been completed.
  • Page 6: Testing And Commissioning

    Light the fire and check for gas soundness. In the event that the inlet pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be commissioned, and the problem investigated and rectified. © 2016 Focal Point Fires plc.
  • Page 7: Decorative Frame

    13. Check the purpose provided ventilation is un-obstructed. 14. Light the fire and test operating pressures. 15. Check safe operation of the appliance by performing a combustion test as detailed in section 10.3. For specific servicing instructions, see relevant sections. © 2016 Focal Point Fires plc.
  • Page 8: Servicing The Burner Unit

    100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation. © 2016 Focal Point Fires plc.
  • Page 9: Troubleshooting Guide

    • Leakage occurring. Carry out leakage test and rectify any problems. • Combustible materials used in incorrect positions. • Airborne substances such as cleaning materials/air fresheners are being drawn through the fire. • Other airborne contaminants such as dust, tobacco smoke, paint vapours. © 2016 Focal Point Fires plc.
  • Page 10: Outlet Openings : Figure

    The appliance must not be positioned vertically within 60mm (2.4”) of a solid floor (i.e. wood or stone) or hearth. This dimen- sion is measured vertically to the bottom of the appliance firebox. © 2016 Focal Point Fires plc.
  • Page 11: Clearances To Combustibles

    If the appliance is used in a room as the sole source of heat, then condensation may occur on colder surfaces within the room. This appliance must not be used in bathrooms and bedrooms. © 2016 Focal Point Fires plc.
  • Page 12: Combustion Monitoring System

    Pilot assembly - Natural gas models (Copreci 21100) F730048 Pilot assembly - LPG models(Seagas P5-19) F730086 Gas valve TRAY105 Burner unit (L30S Natural gas models) F780079 Catalyst (seal kit must also be supplied) F940136 Seal kit for Catalyst © 2016 Focal Point Fires plc.
  • Page 13: Installation Details

    Please note that this does not affect your statutory rights. As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. © 2016 Focal Point Fires plc.
  • Page 14 EKO Fires L30 Flueless Gas Fire ENERGIA · · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE 2015/1186...
  • Page 15 Product Fiche Supplier's name or trademark;  EKO Fires  Model identifier;   L30 Flueless Gas Fire   Gas Category/Pressure = I (20)  Energy Efficiency Class of the model;  A  Direct heat output;  2.3 kW  Indirect heat output;  N.A.  Energy Efficiency Index;  91  Useful Energy Efficiency at nominal heat output;  100%  Useful Energy Efficiency at minimum load;  100%  Specific precautions that shall be taken when the local space heater is assembled, installed or  maintained;  This appliance must be installed, commissioned and maintained by a competent person. Prior to  installation the competent person must ensure that the local distribution conditions (identification  of the type of gas and pressure) and adjustment of the appliance are compatible.  This appliance must be installed in accordance with the rules in force, and used only in a sufficiently  ventilated space of adequate volume. Consult the instructions before installation and use of this  appliance.  The competent person must refer to and comply with the specific instructions listed in the  Installation Manual before starting to install and commission the appliance. ...
  • Page 16 Table 1  Information requirements for gaseous/liquid fuel local space heaters  L30 Flueless Gas Fire Model identifier(s):       [yes/no]  Indirect heating functionality:       (kW) Direct heat output:       N.A. Indirect heat output:       Fuel    Space heating emissions(*)    Select fuel type  [gaseous/liquid] [specify]   [mg/kWh  (GCV)  input   Gaseous Natural Gas < 130 t.b.c.        Item  Symbol  Value  Unit Item Symbol ...
  • Page 17 LPG L30 Flueless Gas EKO Fires Fire ENERGIA · · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE 2015/1186...
  • Page 18 Product Fiche Supplier's name or trademark;  EKO Fires  Model identifier;   L30 Flueless Gas Fire   Gas Category/Pressure = I (37)  Energy Efficiency Class of the model;  A  Direct heat output;  2.0 kW  Indirect heat output;  N.A.  Energy Efficiency Index;  91  Useful Energy Efficiency at nominal heat output;  100%  Useful Energy Efficiency at minimum load;  100%  Specific precautions that shall be taken when the local space heater is assembled, installed or  maintained;  This appliance must be installed, commissioned and maintained by a competent person. Prior to  installation the competent person must ensure that the local distribution conditions (identification  of the type of gas and pressure) and adjustment of the appliance are compatible.  This appliance must be installed in accordance with the rules in force, and used only in a sufficiently  ventilated space of adequate volume. Consult the instructions before installation and use of this  appliance.  The competent person must refer to and comply with the specific instructions listed in the  Installation Manual before starting to install and commission the appliance. ...
  • Page 19 Table 1  Information requirements for gaseous/liquid fuel local space heaters  L30 Flueless Gas Fire ‐ LPG Model identifier(s):       [yes/no]  Indirect heating functionality:       (kW) Direct heat output:       N.A. Indirect heat output:       Fuel    Space heating emissions(*)    Select fuel type  [gaseous/liquid] [specify]   [mg/kWh  (GCV)  input   Gaseous Propane < 130 t.b.c.        Item  Symbol  Value  Unit Item Symbol ...