CKD PFD Series Instruction Manual

Compressed air flow sensor

Advertisement

Quick Links

INSTRUCTION MANUAL
COMPRESSED
AIR FLOW SENSOR
PFD Series
PFK Series
Please read this instruction manual carefully
before using this product, particularly the
section describing safety.
Retain this instruction manual with the
product for further consultation whenever
necessary.
SM-375524-A
Ver.3

Advertisement

Table of Contents
loading

Summary of Contents for CKD PFD Series

  • Page 1 SM-375524-A INSTRUCTION MANUAL COMPRESSED AIR FLOW SENSOR PFD Series PFK Series Please read this instruction manual carefully ● before using this product, particularly the section describing safety. Retain this instruction manual with the ● product for further consultation whenever necessary.
  • Page 3: Safety Precautions

    ! Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanical mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured.
  • Page 4 Items Related to Design and Selection Specification check Never use for flammable fluids. ! DANGER: Use within the specification range characteristic to the product. ! WARNING: The product is designed for use only in the compressed air system. Fracture and malfunction will be caused at pressures or temperatures outside the specification range.
  • Page 5: Operating Environment

    Operating environment Never use in the explosive gas atmosphere. Because the ! DANGER: product does not have an explosion-proof structure, explosion and fire may be caused. If the product is used for nitrogen gas, there is danger of oxygen deficiency. Follow the precautions below and take sufficient care of handling.
  • Page 6 Items Related to Installation and Adjustment Installation Use at specification source voltage and output. ! DANGER: If voltages exceeding the specification voltage limit are added, malfunction, sensor breakage and electric shock and fire will be caused. Do not use loads exceeding the output rating. Otherwise breakage in the output circuit and/or fire will be caused.
  • Page 7 CAUTION: ! The product is designed to have no resistance against lightning surges. Though the product complies with CE marking, no resistance against lightning surges is designed. Take protective measures against lightning surges on the equipment side if necessary. Do not allow repetitive bending forces or tension applied on lead wires.
  • Page 8 When connecting pipes, tighten to the correct torque. CAUTION: ! (1) Prevention of air leaks and thread breakage is the purpose. (2) To avoid damage on the thread, tighten by hand first, then use a tool. Connecting Recommended screw tightening torque [Nm] Rc3/8 22 to 24 Rc1/2...
  • Page 9 When using an elbow or bushing in piping, it is recommended ! CAUTION: to install a direct pipe of 10D or over (in case of primary circuit) or 5D or over (in case of secondary circuit). (1) Be sure to install a direct pipe for the PFD-163 Series. (2) The difference of bores changed with a bushing may not be two or more sizes.
  • Page 10 Items Related to Operation and Maintenance During operation If the valve leading to the sensor is opened quickly, several ten ! WARNING: folds of the rated flow will occur, causing breakage of the platinum thin film sensor and rectifying unit, possibly resulting in an outflow to the secondary circuit.
  • Page 11 INDEX PFD series Instruction Manual No. SM-375524 Items Related to Design and Selection ............2 Items Related to Installation and Adjustment ..........4 Items Related to Operation and Maintenance ..........8 Installation and Wiring Method 1.1 Piping Method ................... 10 1.2 Sensor Section and Monitor Section Wiring Method .......
  • Page 12: Installation And Wiring

    INSTALLATION & WIRING Installation and Wiring Method ! CAUTION: 1.1 Piping Method It is important to prevent foreign matters in pipes (1) Route pipes so that the fluid direction matches the from entering pneumatic devices. Do not remove the package from pneumatic direction specified on the sensor.
  • Page 13 INSTALLATION & WIRING 1.2 Sensor Section and Monitor Section Wiring Method Be sure to refer to operating precautions before performing wiring. PFD Series ! CAUTION: Turn the power off before Route cables separately from noise ! CAUTION: performing wiring. sources...
  • Page 14: Monitor Section

    INSTALLATION & WIRING PFK Series Turn the power off before performing wiring. ! The switch output of PFK Series is only one point: CAUTION: OUT2. To extend the cable, contact us. Monitor section Banana Socket   ① : Analog output (-) Banana Socket  ...
  • Page 15 INSTALLATION & WIRING Electric Wiring If a fault is found during operation, turn the power Do not short circuit in output transistors. off immediately and stop operating, and contact If the load is short circuited, an over-current the sales shop. protection circuit is activated to prevent the For ten seconds after the power is turned on, the output transistors from being broken, while they...
  • Page 16 Max. rated voltage 30VDC Max. rated current 50mA *1: For the model number, refer to pages 33 and 34. <Input for resetting the cumulative flow rate> PFD Series only (1) External input Reset switch (9) GND (common) − 14 −...
  • Page 17: Operation Method

    OPERATION METHOD Operation Method Name and Function of Each Part Operation Function Description method Flow rate display function The momentary or cumulative flow rate is displayed. Analog output function A voltage or current proportionate to the momentary flow rate is output. The flow rate is accumulated.
  • Page 18 OPERATION METHOD 2.2 Switch Parameter Four types of settings can be given according to the purpose. Parameter 0 Parameter 2 No hysteresis setting is provided. Setting Cumulative flow rate Momentary flow rate * Specify the hysteresis if the Parameter 3 Parameter 1 switch chatters due to pulsation of the flow rate.
  • Page 19 OPERATION METHOD [Momentary flow rate display] 2.3 Operation Method (List) Measurement mode The unit alternates each time [CHANGE] is pressed. Press and hold [CHANGE] for five seconds at the desired unit to settle the state. Read mode Parameter display Low display High display Hysteresis display Peak value display...
  • Page 20 OPERATION METHOD Cumulative [Cumulative flow measurement rate display] pause/start After ten seconds, the cumulative [Cumulative flow rate display] value is reset. In the cumulative flow rate display mode, you can pause or reset the value. [Cumulative flow To reset, press and hold rate display] for ten seconds, similarly to the read mode.
  • Page 21 With the PFD Series, you can supply an external input (at pin (1)) to reset the cumulative value, too. (With the PFK Series, the cumulative value is not reset through external inputs. Use button operation only.)
  • Page 22 OPERATION METHOD 2.4.3 Backing up the cumulative flow rate and peak value With this product, the cumulative flow rate and peak value are automatically backed up in the internal memory and the backed-up data is retained even if the power is turned off. The data is backed up at the following timing.
  • Page 23 OPERATION METHOD 2.5 Using the Switch Output Function 2.5.1 Using the range designation mode (OUT1/OUT2) H (upper limit) Inside range mode Parameter 0 The switch output is turned on if the measurement L (lower limit) is within the specified range. Output H (upper limit) Outside range mode...
  • Page 24 OPERATION METHOD (4) Settling the parameter for OUT1 0000 After checking that "1P00" is displayed, press TOTAL L/min(nor) key to settle the setting. READ (5) L (lower limit) setting of OUT1 0100 Using the keys, change the L setting. TOTAL L/min(nor) (To change from 0 to 100, press the shift key once and up key once.)
  • Page 25 OPERATION METHOD 2P00 (10) Settling the h setting for OUT1 TOTAL L/min(nor) Press the key to settle the setting. Transition to OUT2 setting occurs. READ 2P01 (11) Setting the parameter for OUT2 Press the key once to enter "2P01." TOTAL L/min(nor) READ 1回...
  • Page 26 OPERATION METHOD 0000 (16) Settling the H setting for OUT2 TOTAL L/min(nor) Press the key to settle the setting. READ 0010 (17) h (hysteresis) setting of OUT2 Using the keys, change the h setting. TOTAL L/min(nor) (To change from 0 to 10, press the shift key twice and up key once.) READ (18) Settling the h setting for OUT2...
  • Page 27 OPERATION METHOD 2.5.2 Using the accumulation limiter mode (OUT1/OUT2) Parameter 2 The switch output is turned on at the specified cumulative flow rate. For the switch output connection method, refer to Specified cumulative value Section 1.3 Electric Wiring. ex) With PFD-501-10A0 Output ON...
  • Page 28 OPERATION METHOD (6) Entering cumulative flow rate setting 0200 Press the keys to change the cumulative flow TOTAL L/min(nor) rate setting. Nine digits of the cumulative flow rate setting are displayed in ], [m ] or [L]. READ Press the key to shift the digit (unit).
  • Page 29 OPERATION METHOD 2.5.3 Outputting cumulative pulses (OUT2 only) Parameter 3 Cumulative pulses are output. For the cumulative pulse connection method, refer to Section 1.3 Electric Wiring. The cumulative pulse output setting is for OUT2 only. (Unavailable for OUT1) [L (normal)] PFD-501 PFD-102 PFD-202...
  • Page 30 MEMO − 28 − [SM-375524-A]...
  • Page 31: Error Code

    OPERATION METHOD 2.6 Error Code Error code Condition for Switch and analog outputs at error Description of error Remedy (error indication) resetting occurrence (1) Connector cable (1) Check wiring of the Er01 connection fault connector cable. (2) Mixing of fluid other than (2) Do not supply fluids other air or N2 than air and N2.
  • Page 32 PRODUCT Product 3.1 Components and Accessories ■■ PFD series ■■ ● Sensor ● Monitor ● Standard cable ● Operation manual ■■ PFK series ■■ ● Sensor ● Trunk case (Monitor) ● Extension cable ● Power cable ● Coupler ● Operation manual −...
  • Page 33: Specifications

    PRODUCT 3.2 Specifications PFD Series Item PFD-501-10 PFD-102-15 PFD-202-20 PFD-402-25 PFD-802-40 PFD-163-50 [L/min ( normal)] 25 to 500 50 to 1000 100 to 2000 200 to 4000 400 to 8000 800 to 16000 Flow rate range Bore size Rc3/8 Rc1/2...
  • Page 34 PRODUCT PFK Series PFK-501-15N0 PFK-102-15N0 PFK-202-25N0 PFK-402-25N0 PFK-802-40N0 Item 25 to 500 50 to 1000 100 to 2000 200 to 4000 400 to 8000 Flow rate range [L/min(normal)] Rc1/2 Rc1 1/2 Bore size Clean compressed air and nitrogen gas Applicable fluid JIS B8392-1: 2003/1.1.1 to 1.6.1 (Note 1) Quality of air to be used Max.
  • Page 35 PRODUCT 3.3 How to Order PFD Series Separate display type Symbol Symbol Flow rate range 25 to 500 L/min (normal) 50 to 1000 L/min (normal) 100 to 2000 L/min (normal) 200 to 4000 L/min (normal) 400 to 8000 L/min (normal) 0.80 to 16.00 m...
  • Page 36 PRODUCT PFK Series Tester kit Symbol Symbol Flow rate range 25 to 500 L/min (normal) 50 to 1000 L/min (normal) 100 to 2000 L/min (normal) 200 to 4000 L/min (normal) 400 to 8000 L/min (normal) Bore size Coupler for 15A; applicable to 501 and 102 Coupler for 25A;...
  • Page 37: Dimensioned Drawing

    PRODUCT 3.4 Dimensioned Drawing PFD Series <Monitor section> < panel mount fixture > < panel cut dimension > <Sensor section> ● PFD-501/102/202/402/802 Model number Bore size Standard cable (3m) (Note) Attached to product Rc3/8 PFD-501-10 Rc1/2 PFD-102-15 PFD-202-20 Rc3/4 PFD-402-25...
  • Page 38 PRODUCT ● PFD-501/102/202/4 ■■ PFK series ■■ Sensor for PFK-501/102 Rc1/2 Sensor for PFK-202 Sensor for PFK-402 Sensor for PFK-802 Rc1 1/2 − 36 − [SM-375524-A]...
  • Page 39 PRODUCT 3.5 Internal Structure and Parts List Item Item Part name Material Part name Material name name Platinum thin film sensor 1 Aluminum oxide/Platinum O ring Nitrile rubber Platinum thin film sensor 2 Aluminum oxide/Platinum Sensor base PCB Glass epoxy Body A6063S Aluminum alloy...
  • Page 40 MEMO − 38 − [SM-375524-A]...