CKD PPX Series Manual

Digital pressure sensor
Hide thumbs Also See for PPX Series:

Advertisement

New product
Visibility is improved with digital twin display!
Digital pressure sensor
PPX Series
DIGITAL PRESSURE SENSOR PPX SERIES
CC-825A 5

Advertisement

Table of Contents
loading

Summary of Contents for CKD PPX Series

  • Page 1 New product Visibility is improved with digital twin display! Digital pressure sensor PPX Series DIGITAL PRESSURE SENSOR PPX SERIES CC-825A 5...
  • Page 4 Digital pressure sensor applications Positive pressure and vacuum confirmation or interlock High function type Easy setting with auto reference/remote zero adjusting VRA2000 Manifold Both vacuum pressure and burst pressure can be controlled with a single unit. Magnetic spring buffer FBU2 Contact confirmation Intro 1...
  • Page 5 M E M O M E M O Intro 2...
  • Page 6 Digital pressure sensor Series JIS symbol Spec i f ic a ti on s Standard type High function type Descriptions For low pressure For high pressure For low pressure For high pressure PPX-R01* PPX-R10* PPX-R01*H PPX-R10*H Kind of pressure Gauge pressure Rated pressure -100.0 to +100.0kPa -0.100 to +1.000MPa...
  • Page 7 Series How to order How to order Symbol Descriptions <How to order for domestic market> Pressure range -100.0 to 100.0kPa -0.100 to 1.000MPa Output type Pressure range NPN transistor output 2 point (standard type) Output type PNP transistor output 2 point (standard type) NPN transistor output 1 point + analog voltage/current output or external input (high function type) PNP transistor output 1 point + analog voltage/current output or external input (high function type) Piping shape...
  • Page 8 Series Analog output voltage - pressure characteristics PPX-R01NH R01PH Pressure -100.0 100.0 (kPa) PPX-R10NH R10PH Pressure -0.100 1.000 (MPa) Analog output current - pressure characteristics PPX-R01NH R01PH Pressure -100.0 100.0 (kPa) PPX-R10NH R10PH Pressure -0.100 1.000 (MPa)
  • Page 9: Series Dimensions

    Series Dimensions Dimensions PPX-R**-6M/6N (R/NPT thread) Sub-display section (4 digit LCD display) Main display section (4 digit LCD display) 42.5 Connector Pressure unit 25.5 R1/8 M5 female thread Setting DOWN key NPT1/8 Output 1 operational indicator light M3 female thread depth 4 Setting UP key Output 2 operational indicator light or analog...
  • Page 10: Panel Cut Dimensions

    Series Dimensions with options Bracket (PPX-KL) Installation drawing 42.5 NPT1/8 R1/8 (5.3) Weight: 15 g Panel bracket (PPX-KHS) installation drawing 33.4 18.3 34.5 Connector Weight: 6 g Panel thickness 0.5 to 6 Panel cut dimensions Installing 1 pc. Installing consecutive n pcs. horizontally. Installing consecutive n pcs.
  • Page 11 Series Dimensions with options Dimensions with options Front protective cover (PPX-KCB) installation drawing Front protective cover 18.3 39.3 33.4 34.5 Connector Panel thickness 0.5 to 6 Weight: 3g Cable with connector (PPX-C*) (35) (50) Conductor cross-section areas 0.2mm 3.7 cable Insulator outer diameter of 1.1mm (JST MFG CO.
  • Page 12 Series Circuit and connection NPN output type Standard type (Brown) +V Load (Black) comparison output 1 Load 12 to 24 VDC 100mA MAX. ±10% (White) comparison output 2 100mA MAX. (Blue) 0V High function type <External input connection sample> (Brown) +V (Brown) +V (White) (White) analog voltage/current...
  • Page 13 Digital pressure sensor Oil-prohibited type PPX-P12 Series JIS symbol S p e cif ica t io n s Overview Specifications are the same as standard type. Oil-prohibited treatment (degreasing) at gas Refer to page 1 for details. contact areas (piping ports, etc.) Silicone grease-free at gas contact areas (no grease used at gas contact areas) Features...
  • Page 14 Series Operation mode and output operation Unit display part (Note 1) (Note 2) Output 1 operational indicator light Main display Comparison output 1 ON lighting Output 2 operational/Analog Sub-display section Connector voltage output indicator light Standard type: Lighting when Comparison output 2 ON High function type: Lighting when Analog voltage/current output is set...
  • Page 15: Run Mode

    Series Operation RUN MODE Setting threshold See "Menu setting mode", Comparison output 1/2 output mode setting, and Analog voltage/current output/external input switching for details on setting. Threshold will be set on sub display part. Main display part will not be changed. The display changes when the MODE key is pressed.
  • Page 16: Menu Setting Mode

    Series Menu setting mode If the mode switching key is held down long while a setting is made, the RUN mode opens and changed items are set. RUN MODE MODE Hold down for 2 secs. <Setting comparison output 1 output mode> Window Hysteresis comparator...
  • Page 17 Series Operation Setting descriptions Initial status Descriptions Setting comparison output Set comparison output 1 output mode. 1 output mode Setting comparison output 2 output mode Set comparison output 2 output mode. (Only standard type) Analog voltage/current output/ Analog voltage, current output, auto reference input, or remote zero adjusting input can be external input switching switched.
  • Page 18: Pro Mode

    Series PRO MODE The mode will be switched to PRO MODE if the mode switchover key is held down for 4 seconds during RUN MODE. Hold down the mode switchover key for several seconds to switch to RUN MODE during the setting. In that case, the changed descriptions are set. The left end display section is in the initial state.
  • Page 19 Series How to operate Setting descriptions Descriptions Initial status Sub-display section display during RUN MODE can be switched. " ": Nothing is displayed. Sub-display section switching " ": The current pressure unit is displayed. " ": Specified number is displayed. "...
  • Page 20 Series Setting copy function This makes a copy of setting details to the slave side sensor from the master side sensor. A copy between different models cannot be made. The setting copy function applies to one slave side sensor per master side sensor. <Installation procedure>...
  • Page 21: Error Display

    Series How to operate Operation chart <Normal (N.O. setting for each comparison output)> Auto reference input (N.O. setting for each comparison output) Detection pressure when auto reference input: 10kPa Output mode: Hysteresis mode Output Output Impressed pressure (kPa) Impressed pressure (kPa) Displayed value (kPa) Displayed value (kPa) P(a)
  • Page 22 Series Example of setting operation per application EASY MODE (Note 1): This is the example of setting from default setting (default). (Note 2): If the setting conditions are unknown, operate <reset setting> in PRO MODE, and reset to default before using. Suction confirmation To EASY MODE R01 type (-100.0 to 100.0kPa)
  • Page 23 Series How to operate Example of setting operation per application HYS MODE (hysteresis mode) (Note 1): This is an example of setting from default setting. (Note 2): If the setting conditions are unknown, operate <reset setting> in PRO MODE, and reset to default before using. Suction confirmation To HYS MODE (hysteresis mode) Comparison output 1...
  • Page 24 Series Example of setting operation per application WCMP MODE (window comparator mode) (Note 1): This is an example of setting from default setting. (Note 2): If the setting conditions are unknown, operate <reset setting> in PRO MODE, and reset to default before using. Source pressure confirmation To WCMP MODE (window comparator mode) R10 type (-0.100 to 1.000MPa)
  • Page 25: Safety Precautions

    Scope of warranty In case any defect attributable to CKD is found during the term of warranty, CKD shall, at its own discretion repair the defect or replace the relevant product in whole or in part, according to its judgement.
  • Page 26: Design & Selection

    Power supply voltage Use conditions to comply with CE marking Use the product within the specified power supply voltage PPX Series is CE marked products complied with EMC range. If voltage exceeding specified range is applied, or directive. EN61000-6-2 regulation matched to immunity current power (100 V AC) is applied, circuit damage could applies to this product.
  • Page 27: Installation And Adjustment

    Series Precautions Installation & Adjustment WARNING Piping Avoid incorrect connection. Apply a 12mm spanner (14mm for PPX-6G type) An incorrect connection may cause a fatal error not only to on the pressure port hexagon head section to fix, this product but also peripheral devices. then apply tightening torque 9.8N·m or less if a commercially available joint is connected to the DC power not insulated from AC primary side may pressure port.
  • Page 28 Series Installation & Adjustment CAUTION Voltage must rise or fall quickly when power is turned ON or OFF. If the rated voltage is not reached, the sensor Care must be taken for protection of body and lead wire. could malfunction. In some cases, the sensor could not Do not apply stress recover after the rated voltage is reached.
  • Page 29 Surge absorbing (later installation) element (integrated) Disassembling the product could result in damage or deterioration of the product. CKD will not guarantee the performance after disassembling. When replacing or moving the product, remove Pressure switch Solenoid valve the sensor without disassembling pressurized port.
  • Page 30: Related Products

    Series Related products Vacuum regulator EVR Series Catalog no. CC-1174A ■ High precision pressure accuracy Hysteresis: 0.3% F.S., linearity: ±0.5%F.S., resolution: 0.1%F.S., repeatability: 0.2%F.S. ■ Improved temperature stability and durability Zero point fluctuation: 0.06%F.S., span fluctuation: 0.06%F.S., durability: 3 times (compared with previous models) ■...
  • Page 31 Series Related products Related products FRL Module type Catalog no. CB-024SA Digital pressure sensor PPX is equipped as option for FRL modular type combination, filter regulator, and regulator.
  • Page 32 If the goods and their replicas, or the technology and software in this catalog are to be exported, laws require the exporter to make sure they will never be used for the development or the manufacture of weapons for mass destruction. ● Specifications are subject to change without notice. CKD Corporation 2014 All copy rights reserved. 2014.10...

Table of Contents