Filters
1.
Open the front panel.
2.
Remove the air fi lter.
Press the claws on the right and left of the air fi lter down slightly, then pull upward.
3.
Take off the titanium apatite photocatalytic
air-purifying fi lter.
Hold the tabs of the frame, and remove the claws in 4 places.
4.
Clean or replace each fi lter.
See fi gure.
5.
Set the air fi lter and titanium apatite photocatalytic air-purifying
fi lter as they were and close the front panel.
Operation without air fi lters may result in troubles as dust will accumulate inside the indoor unit.
Insert the 2 tabs on the lower side of air fi lter into the body.
Then, insert the 2 tabs on the upper side into the body.
Insert the tab on the right side into the body.
Close the panel slowly.
Slide the 2 stoppers on the left and right sides
outward until they click.
CAUTION
Do not touch the aluminum fi ns by bare hand at the time of dismounting or mounting the fi lter.