Do not weld or flame cut on pipes, tubes, or tanks that contain flammable fluids or gases.
Ether and starting fluid are flammable. Do not smoke when using. Always follow the
instructions on the can and in the manufacturer's manual for your trowel.
Always use a safe, nonflammable solvent when you clean parts. Do not use flammable fluids
or fluids that give off harmful vapors.
Store all flammable fluids and materials away from your work area. Whenever the sparkplug
is removed, do not test for spark on gasoline powered engines if the smell of gasoline is
present. A stray spark could ignite fumes.
Know where fire extinguishers are kept – how they operate – and for what type of
fire they are intended!
EXHAUST FUMES
Engine exhaust fumes can cause sickness or death. When performing
maintenance, if it is necessary to run an engine in an enclosed area, remove
the exhaust fumes from the area when an exhaust pipe extension. If you do
not have an exhaust pipe extension, make sure you open the doors and get
outside air into the area. Ensure that permissible carbon monoxide levels are
monitored
and
Never siphon gasoline or hydraulic fluid using a hose and suction by mouth
Ingestion of these fluids even in small amounts will require immediate medical
attention and can cause death.
COOLING SYSTEM
Maintain the cooling system according to the manufacturer's instructions.
Hot coolant can spray out and you can be burned if you improperly maintain or service the
cooling system.
Remove filler cap only when cool.
TROWEL BLADES AND PANS
• Do not attempt to clean, service or perform adjustments on the trowel while it is running.
• Do not remove while the trowel is hanging overhead. Always support the trowel
securely on a flat, level surface before changing blades or pans.
• Always handle blades and pans carefully. Worn blades or pans may develop sharp
edges that can cause serious cuts.
Always replace worn or damaged parts with service parts designated by the
manufacturer.
• Replace blades and pans as a complete set – even if only one blade or pan is showing
wear or damage. They can wear differently depending on different jobs, and a difference
in blade size will damage the finish of the slab surface.
HYDRAULIC SYSTEMS
Inspect electrical wiring or worn or frayed insulation. Install new
wiring if wires are damaged
not
exceeded.