FR Instructions de montage / Mode d'emploi / Garantie
ES Instrucciones de montaje / Manejo / Garantía
Locarno Thermostatic Trim with
Volume Control and Diverter
04820xx0

Advertisement

loading
Need help?

Need help?

Do you have a question about the Locarno Thermostatic Trim with Volume Control and Diverter 04820250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hans Grohe Locarno Thermostatic Trim with Volume Control and Diverter 04820250

  • Page 1 EN Installation / User Instructions / Warranty FR Instructions de montage / Mode d'emploi / Garantie ES Instrucciones de montaje / Manejo / Garantía Locarno Thermostatic Trim with Volume Control and Diverter 04820xx0...
  • Page 2 English Français Technical Information Données techniques Water pressure Pression d’eau Recommended 15 - 75 PSI (0.1 - 0.5 MPa) recommandée 15 - 75 PSI (0.1 - 0.5 MPa) Maximum 145 PSI (1 MPa) maximum 145 PSI (1 MPa) Hot water temp. Température d’eau chaude Recommended 120°-140°...
  • Page 3 Español Datos tecnicos Tools Required / Outiles Utiles / Herramientas Útiles Presión en servicio recomendada 15 - 75 PSI (0.1 - 0.5 MPa) max. 145 PSI (1 MPa) Temperatura del agua caliente recomendada 120°-140° F (48° - 60° C)* max. 158°F (70°...
  • Page 4 Locarno 04820xx0 1⅞"-3" 6⅞" (174 mm) (47-75 mm) Ø2" ⅝" (17 mm) (51 mm) 2¾"-3⅞" Ø2⅝" (71-99 mm) (66 mm) Service Stops / Butées d’arrêt d’isolation / Cierres de servicio closed ferme cerrado open 4 mm ouvert abierto 4 mm Important Avis Importante...
  • Page 5 Installation Suggestions / Suggestions d'installation / Sugerencias para la instalación The measurements shown are suggestions. They may be 04823xx0 altered to suit the needs and + 04833xx0 preferences of the homeowner. *Know and follow all applica- ble local plumbing codes when 01850181 + 04820XXX determining the location of the Thermostatic Mixer Trim...
  • Page 6 Flush the hot and cold supplies / Rincez les conduites d’alimentation de l’eau chaude et de l’eau froide / Lave los suministros frío y caliente 90° > 5 min 4 mm 4 mm > 5 min English Français Español Remove the dust cover. Retirez l’étiquette.
  • Page 7 90° 4 mm 4 mm English Français Español Close the stops. Fermez l’eau chaude et Cierre los pasos del agua l’eau froid caliente y del agua fría en los à les butées d’arrêt cierres de servicio. d’isolation.
  • Page 8: Installation / Installation / Instalación

    Installation / Installation / Instalación ¹ ⁄ ₁ ₆ " - ⅛ " 1 - 2 5 mm English Français Español Close the stops. Fermez l’eau à Cierre el paso del agua les butées d'arrêt en la entrada del sum- Cut the plaster shield so that it d'isolation.
  • Page 9 4 mm 3.6 ft-lb 5 Nm English Français Español Install the function block. Insérez le bloc de fonction. Inserte el bloque de función. Install and tighten the function Installez les vis du bloc de Instale los tornillos del bloque block screws. fonction.
  • Page 10 English Français Español Add ½" to this measurement. Ajoutez ½ po à cette longueur Agregue ½" a X. Anote esta « X ». Notez cette nouvelle medida. Cut each screw so that it is X + longueur. ½" long. Corte el tornillo de modo que Coupez les vis de façon à...
  • Page 11 4 mm 90° 90° English Français Español Open the stops. Ouvrez l’eau à les butées d'ar- Abra el paso del agua en los rêt d'isolation. cierres de servicio. Install the carrier plate so that the notch is at the bottom. Installez la plaque-support de Instale la placa del portador de façon à...
  • Page 12 ° F ° F English Français Español Install the escutcheon. Installez le rosace. Instale el florón. Install the diverter handle. Installe la poignée d’inverseur. Instale la manija del inversor. Tighten the diverter handle Serrez le vis de la poignée Apriete el tornillo de la manija screw using a 2 mm Allen d’inverseur à...
  • Page 13 ° F ° F English Français Español Turn the diverter handle to the Ouvrez la robinet. Abra la válvula. “on” position. Tournez la tige de la cartouche Gire el vástago del cartucho Turn the thermostatic mixer stem jusqu’à ce que l’eau soit à une hasta que el agua de salida until the output water is 104°F.
  • Page 14 Set the high temperature limit stop / Réglez la butée de limite d’eau chaude / Fije el tope de límite de alta temperatura ° F 2 mm °F 2 mm 3 mm **Follow all applicable local plumbing codes when setting the high temperature limit stop. To prevent scald injury, the maximum output temperature of the shower valve must be no higher than 120°F (49°C).
  • Page 15 3 mm 0.74 ft-lb 1 Nm ° F ° F Justify the handle / Réglez la poignée / Ajuste la manija ° F °F 2 mm 2 mm...
  • Page 16 Replacement Parts / Pièces détachées / Repuestos Locarno 04820xx0 94073000 97350000 98156000 4 mm (36x2) 96525000 98283000 95255000 27 mm 96454000 98133000 98153000 (16x2) 96446xx0 (30x5) 98471000 92594000 98197000 (44x4) (20x1.5) 98146000 98282000 (25x1.5) 92146000 93918xx0 (25x2.5) 98913000 92216xx0 (M34x1.5) 92846000 27 mm 2 mm...
  • Page 17 User Instructions / Instructions de service / Manejo fermé ouvert cerrar abierto ° F ° F ouvert abierto ° F cold froid chaud chaud frío caliente caliente ° F ° F ° F 104° F >104° F...
  • Page 18 Check valve maintenance / Entretien de les clapets anti-retour/ Mantenimiento de las válvulas antirretornos ° F °F 2 mm 2 mm 3 mm °F 4 mm...
  • Page 19 27 mm red / rouge / rojo 27 mm 5.9 ft-lb 8 Nm 4 mm 3.6 ft-lb 5 Nm 0.74 ft-lb 1 Nm...
  • Page 20 ° F ° F 3 mm 3 ft-lb 4 Nm °F ° F 2 mm 2 mm...
  • Page 21: Troubleshooting

    Troubleshooting Problem Possible Cause Solution Insufficient water – Supply pressure inadequate – Check water pressure – Cartridge filters dirty – Clean the filters – Showerhead or handshower – Clean the filter filter dirty Crossflow: hot water forced into – Check valves dirty or worn –...
  • Page 22: Dépannage

    Dépannage Dysfonctionnement Origine Solution Pas assez d´eau – Pression d´alimentation – Contrôlez la pression insuffisante – Filtre de l´élément thermosta- – Nettoyez les filtres tique encrassé – Joint-filtre de douchette – Nettoyez le joint-filtre entre la encrassét douchette et le flexible Circulation opposée, l´eau –...
  • Page 23: Localización De Fallas

    Localización de fallas Problema Causa Solución Sale poca agua – presión insuficiente – comprobar presión – filtro del termoelemento sucio – limpiar filtro – filtro de la ducha sucio – limpiar / cambiar filtros entre flexo y ducha Flujo de agua cruzada agua –...
  • Page 24 Cleaning Recommendation for Hansgrohe Products Modern bathroom faucets, kitchen faucets and shower products are made from different materials to comply with the needs of the market with regard to design and functionality. To avoid damage to the product, it is necessary to take proper care of it.
  • Page 25 Important • Les residus de produits pour le corps comme les savons liquides, shampooings, gels de douche, teintures pour cheveux, parfums, apres-rasage et vernis a ongles peuvent causer des deteriorations. Rincez le produit avec de l’eau propre après chaque utilisation. •...
  • Page 27 Hansgrohe, Inc. Limited Warranty Offering our customers the highest quality at all times is a funda- • abuse, neglect or improper or incorrectly performed mental part of the Hansgrohe, Inc. company philosophy. We of- installation, maintenance or repair, including the use of fer consumers a limited warranty on our hansgrohe and AXOR abrasive or caustic cleaning agents or “no-rinse”...
  • Page 28 TEAR, OUTDOOR USE, MISUSE (INCLUDING USE OF THE This warranty gives you specific legal rights, and you may also PRODUCT FOR AN UNINTENDED APPLICATION), FREEZING have other rights which vary from state to state. WATER, EXCESSIVE WATER PRESSURE, PIPE CORROSION IN PRODUCT I NSTRUC TIONS A ND QUE STIONS THE HOME IN WHICH THE PRODUCT IS INSTALLED, ABUSE, NEGLECT OR IMPROPER OR INCORRECTLY PERFORMED...