Set-Up - Lincoln Electric Dual Maverick 200 Operator's Manual

Table of Contents

Advertisement

DUAL MAVERICK
®
200/200X

SET-UP

The set-up allows for customization of the Maverick. Options
available in the Set-up menu are:
• AUTO-START: NO LOAD PERIOD - When AUTO-START is
enabled, the NO LOAD PERIOD is the period of time the
machine can be running with no auxiliary or weld load before
it automatically shuts down. The user can use this setting to
set the amount of time for the NO LOAD PERIOD.
• TAP START ACTIVE PERIOD - The TAP START ACTIVE
PERIOD is the period of time that the user can restart the
welder after it is shut down due to the NO LOAD PERIOD
when AUTO-START is enabled. In order to restart the welder,
tap the electrode to the work piece. This setting is used to set
the TAP START ACTIVE PERIOD time.
• AUTO-START: ON/OFF - AUTO-START shuts down the engine
when it is not in use for a set period of time and allows the
user to re-start the engine with a "tap" of their electrode onto
their work piece without having to go back to their machine.
• PIN - PIN page is used to set and enable a mandatory
Operator Pin when the machine is turned on and/or a
Supervisor Pin for accessing the Setup page.
• DISPLAY BRIGHTNESS
• DIAGNOSTIC INFORMATION - Diagnostic information page
can be used to get useful information about the welder. ECG
FAULT CODE is the number of pulse detected from ECG fault
lamp. The fault codes can be found in troubleshooting section
(E-4).
• NEW PCB CALIBRATION - When new PCB(s) is installed on
the machine, calibration is needed for both Single and Dual
modes. On Single mode, only follow the instructions on the
left display. On Dual mode, only follow the instructions on the
right display. To ensure proper calibration ensure mode was
in Stick at 150 amps set point before entering setup menu.
Failure to do so will not allow welder to enter calibration
mode.
• VARIABLE SPEED ON/OFF - Turn the variable speed function
off when desired weld output is not reached. For example, in
high altitude areas that have lower oxygen levels, the
operator can turn off the variable speed function to increase
weld output.
• RESTORE FACTORY SETTINGS
• MACHINE SELECT - When a new PCB(s) is installed on the
machine, the PCB has to go through a "Machine Select"
process. This setup option should only be used if the initial
"Machine Select" process was not completed successfully.
To enter this setup option use the following pass code: 3210.
Ensure the correct K # and Code number is used for the
machine. Failure to do so can permanently damage the
welder.
• CROSSLINC ON/OFF
• SPOOL GUN CALIBRATION - When first connecting a spool
gun to the machine, the engine power must be calibrated for
the spool gun to have the wire feed speed be accurate.
• ENGINE SERVICE KIT - Provides useful information regarding
replacement parts needed during the service of the Dual
Maverick 200/200X.
• PRODUCTIVITY METRICS - Provides useful information and
statistics regarding how the machine is being used.
Auto-Start: No Load Period
Tap Start Active Period
Auto-Start: On/Off
PIN
Display Brightness
Diagnostic information
Press knob to select
B-19