6-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)
1
Example: Combination Remote Amperage Control (Stick)
Set Remote
Set V/A
Adjust Switch
Process
Example: Combination Remote Amperage Control (TIG)
Set V/A
Set Remote
Process
Adjust Switch
OM-497 Page 28
Set Range
Control Not
Used In Remote
Stick Mode
Set Range
Set Control
1
Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 4-11).
In Example:
Process = Stick (Using Remote On/Off)
Range = 90 to 240 A DC
Min = 90 A DC
Max = 240 A DC
Max (240 A DC)
Min (90 A DC)
Adjust Optional Remote Control
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 160 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 100 A DC (50% of 40 to 160)
Max (100 A DC)
Min (40 A DC)
Adjust Optional Remote Control
0774 / Ref. 197 785 / 802 311