5-3. Remote Amperage Control On CC Models (Optional)
1
Example: Combination Remote Amperage Control (Stick)
Set Switches
OM-497 Page 24
Set Range
1
Connect optional remote control to
RC13 (see Section 4-10).
Range = 120 to 250 A DC
Percentage Of Range = 50%
Max = About 185 A DC (50% of 120 to 250)
Set Control
0774 / Ref. 154 862-A / Ref. 181 711-A / 802 311
Remote Amperage Adjust
Receptacle RC13
In Example:
Max (185 A DC)
Min (74 A DC)
Adjust Optional Remote Control