4-1. Installing Welding Generator (See Sections 4-2 And 4-3)
Movement
OR
Grounding
2
4-2. Using Lifting Eye
OM-497 Page 14
SECTION 4 − INSTALLATION
Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
1
OR
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
3
4
GND/PE
2
install1 12/99 − Ref. 800 652 / Ref. 800 477-A / 158 936-A / 0854
1
2
3
Location
OR
Y Always
ground
generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y If unit does not have GFCI re-
ceptacles, use GFCI-protected
extension cord.
1
Lifting Eye
2
Nut
3
Carriage Bolt
Raise lifting eye until it snaps in
place. Lower lifting eye when not
needed.
To lock the lifting eye in the upright
position, insert a 1/4-20 x 1-1/2 in
carriage bolt through slot in bracket
and secure with nut (bolt and nut not
supplied).
Tools Needed:
Ref. 802 169-A / Ref. 802 311