This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Topic
1783-MMS10A Series B, 1783-MMS10AR Series B, and 1783-MMX8TA Series A Catalog Numbers Added
Installation Instructions Original Instructions Stratix 5800 Ethernet Managed Switches Catalog Numbers 1783-MMS10 Series A, 1783-MMS10A, 1783-MSS10AR Series B, 1783-MMS10E Series A, 1783-MMS10B Series A, 1783-MMS10BE Series A, 1783-MMS10 Series B, 1783-MMS10E Series B, 1783-MMS10B Series B, 1783-MMS10BE Series B, 1783-MMS10R Series B, 1783-MMS10ER Series B, 1783- MMS10EA Series B, 1783-MMS10EAR Series B, 1783-MMX8T Series A, 1783-MMX8E Series A, 1783-MMX8EA Series A, 1783-MMX8S Series A, 1783-MMX8SA Series A, 1783-MMX8TA Series A, 1783-MMX6T2S Series A, 1783-MMX16T Series A, 1783-MMX16E Series A, 1783-MMX14T2S Series A Topic...
Page 2
Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 3
Secure DIN rail to mounting surface approximately every 200 mm (7.8 in.) and use end-anchors appropriately. Be sure to ground the DIN rail properly. Refer to Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1, for more information.
Page 4
The enclosure must be accessible only by the use of a tool. • This equipment shall be used within its specified ratings defined by Rockwell Automation. • Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the peak rated voltage when applied in Zone 2 environments.
Ethernet connections and configures the interfaces accordingly. You can use a crossover or a straight-through cable for connections to a 10/100/ 1000 port, regardless of the device on the other end of the connection. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Align the tabs on the top and bottom-left rear of module and the holes at the top and bottom-right rear of switch. Press the expansion module and the switch together, so that the electrical connections engage and the screw holes align. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Hold the bottom of the switch away from the DIN rail and place the two hooks on the back of the switch over the top of the DIN rail. To cause the latch at the bottom rear of the switch to move down and snap into place, push the switch toward the DIN rail. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Locate the two power connectors on the switch front panel labeled Pwr A and Pwr B. Identify the positive and return DC power connections by using the labels on the switch panel. DC + Positive DC power connection DC – Return DC power connection Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 9
To apply power to a switch that is directly connected to a DC power source, locate the circuit breaker on the panel board that services the DC circuit. Then switch the circuit breaker to the On position. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 10
For example, to wire an alarm input circuit, complete the IN1 and REF connections External device connection 1 (IN1) External device connection 2 (REF) Use a ratcheting torque screwdriver to tighten the alarm connector captive screw (above the installed wire leads) to 0.23 N•m (2.0 in•lb). Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 11
Use a ratcheting torque screwdriver to tighten the captive screws on the sides of the alarm relay connector. Install or Remove and SFP Module ATTENTION: Use SFP modules from only Rockwell Automation. For details about supported modules, see the Stratix Ethernet Device Specifications Technical Data, publication 1783-TD001.
Page 12
Place it in an anti-static bag to help protect it from static discharge. After the card is installed, close the guard door and fasten the captive screw by using a Phillips screwdriver to keep the door in place. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 13
The Setup status indicator blinks green as the IOS software image loads. If the routine fails, the Setup status indicator turns red. IMPORTANT Startup failures are fatal to the switch. If your switch does not complete the start sequence, contact Rockwell Automation. Remove the Switch from the DIN Rail To remove the switch from a DIN rail, follow these steps.
Page 14
Screw torque, alarm terminals, max 0.23 N•m (2.0 in•lb) Pilot duty rating Alarm not rated North American temp code ATEX temp code Operating temperature ratings apply to switches and any compatible expansion module. Rockwell Automation Publication 1783-IN013C-EN-P - March 2022...
Page 15
Stratix 5800 Ethernet Managed Switches Installation Instructions Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description Stratix Ethernet Device Specifications Technical Data, publication 1783-TD001 Provides specification information for Ethernet switches and other devices. Stratix 5800 Ethernet Managed Switches User Manual, publication 1783-UM012 Provides information about configuring, monitoring, and troubleshooting the switches.
Page 16
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, expanding human possibility, Rockwell Automation, and Stratix, are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Need help?
Do you have a question about the Allen-Bradley Stratix 5800 and is the answer not in the manual?
Questions and answers