T 9800/T 982x
1
Technical Data
Maximum load
Drum volume
Drum speed
Table 030-1: Drum Data
Heating mode
Heater type
Heater output
Temperature sensor
Temperature limiter
Drum light (H3/6)
Table 030-2: Heater Data
Temperature
°F
32
41
50
59
68
77
86
95
104
113
122
131
140
149
158
167
176
185
194
199
203
17.6 lbs (8 kg)
48 gal (180L)
48 rpm
Electric; for gas, refer to Table 031-1.
Duct heater bank (R1, R2, R3); 3-filament
5.2kW (1.90kW, 1.70kW, 1.60kW)
Heater bank NTC (2R30)
3 x 3/4" temperature limiter (F1) with manual reset, 16A
E 14 bayonet closure, activation via relay on the
electronic (EPWL). USA: 120V, 15W
Resistance (kΩ)
Heater bank NTC
°C
(2R30)
0
340
5
261
10
203
15
159
20
126
25
100
30
80.2
35
64.8
40
52.7
45
43.1
50
35.5
55
29.4
60
24.5
65
20.5
70
17.3
75
14.6
80
12.5
85
10.6
90
9.13
93
8.34
95
7.86
21
Technical Information
Drying air NTC
(1R30)
38.0
29.7
23.4
18.6
14.9
12.0
9.73
7.96
6.55
5.42
4.52
3.78
3.19
2.70
2.29
1.96
1.68
1.45
1.25
1.15
1.09