Installing The Unit In The Sunroof; Installing The Electrical Supply Lines - Dometic COOLAIR SP950T Installation Manual

Assembly kit for renault trucks sleeper and high sleeper driver cab
Hide thumbs Also See for COOLAIR SP950T:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Installation
7.5

Installing the unit in the sunroof

➤ Set the unit down centrally aligned and in the direction of travel (fig. 1,
page 3) on the sunroof opening.
I
NOTE
Make sure the air conditioning roof unit is centred perfectly. The seal must be
applied continuously around the air conditioning roof unit after being placed
on the roof of the vehicle. This is the only way to ensure a tight seal.
➤ Place the spacer sleeve L = 18 mm (fig. 5 1, page 4) and the washer M8
(fig. 5 9, page 4) on the fastening drill holes as shown in fig. 5, page 4.
➤ Screw one hex screw M8 x 40 (fig. 5 4, page 4) with a washer (fig. 5 2,
page 4) and spring washer (fig. 5 3, page 4) in the 8 thread inserts on the
bottom of the unit.
A
NOTICE!
Do not exceed the specified torque under any circumstances. This is the only
way to ensure that the thread inserts are not torn out.
➤ Tighten the screws with a torque of 8 Nm.
7.6

Installing the electrical supply lines

!
WARNING!
• The electrical power supply may only be performed by qualified personnel
with specialist knowledge.
• Make sure there is no voltage present on electrically operated components
before carrying out work on them!
A
NOTICE!
• Fit a fuse of 25 A to the connection to the vehicle's power supply.
• The battery must be able to supply the required current and voltage
(chapter "Technical data" on page 28).
I
NOTE
The unit is equipped as standard with a 4 m long cable with a cross-section of
2
6 mm
. If longer cable lengths are required, then the cable cross-section must
be increased by an authorised specialist workshop:
In this case cut off the cable as closely as possible to the unit (max. 0.5 m) and
then establish a suitable connection with a larger cable cross-section.
When the cable is extended by 4 m to 6 m in length, the manufacturer
recommends using a cross-section of at least 8 mm
20
CoolAir SP950T
2
.
EN

Advertisement

Table of Contents
loading

Table of Contents