en | Configuration
*B450 Cellular
For SDI2 control panels using firmware v2.03+, you can use RPS v5.19+ to configure GSM
cellular parameters for the B442 and B443. Refer to RPS and RPS Help for information on
these parameters.
Use RPS settings on Module 1 only. For a second B450 module, you must use the USB menu.
For SDI2 control panels using firmware version v1.00 to v2.02, use the USB interface
connected to the B450.
5.3

USB configuration

For configurations that are not PnP, you can connect a computer directly to the module with
USB. To configure the module, install the USB driver and Tera Term on the connected
computer. The B450 CD-ROM has the RBUS1CP.inf (USB driver) and Tera Term installation
files.
Notice!
RPS users
You can use RPS v5.16 or higher to configure the module through a remote connection to the
control panel, or with a USB connection to the control panel. Refer to RPS configuration, page
21.
Notice!
Male A to Male A cable required
USB configuration requires a Male A to Male A cable. Bosch recommends the B99 cable (P/N:
F01U278853).
Use the USB connection for configuration or diagnostics only. Disconnect the cable when not
in use.
Getting the USB driver and Tera Term
If you do no have the B450 CD-ROM, download the required files from
www.boschsecurity.com. Go to the B450, then to the Software Downloads tab. Click the link
for the driver and Tera Term. Save the file to the computer. This applies to the B450 only.
5.3.1

Get started

Installing the RBUS1CP.inf file USB driver
1.
2.
2018.10 | 10 | F.01U.300.740
Install the RBUS1CP.inf file onto the connected computer.
Open Device Manager to make sure that the INF file installed and shows in the Ports
(COMM & LPT) section.