Power Supply Microprocessor (Dsp) Sequence Of Operation - Lincoln Electric SPIRIT II 275 Technical Manual

Plasma cutting system with fineline high definition technology
Hide thumbs Also See for SPIRIT II 275:
Table of Contents

Advertisement

Section 6: Maintenance &Troubleshooting
Power Supply Microprocessor (DSP)
Sequence of Operation
The following DSP Indicators should illuminate after primary power is applied:
 D77 ................................... 3.3V Supply
 D78 ................................... 1.8V Supply
 D50 ................................... ASC (Door)
 D33 ................................... Coolant Level
 D37 ................................... Arc Hold (if INOVA is being used)
 D10 ................................... RS232 T1 Out (Blinking)
 D11 ................................... CAN RXD (Dim Flashing)
 D12 ................................... CAN TXD (Dim Flashing)
The following DSP Indicators should illuminate when the OFF Button is released:
 D40 ................................... OFF Button
The following DSP Indicators should illuminate when the ON Button is activated:
 Opto U21 .......................... Motor / Solenoid
 Opto U19 .......................... Solenoid (not used)
 Opto U26 .......................... Fan
 D42 ................................... Plasma Ready
The following DSP Indicators should illuminate when a START signal is applied (begin
cut cycle):
 D36 ................................... Start
 Opto U27 .......................... Preflow
 Opto U29 .......................... Shield
 Opto U24 .......................... Surge (only over 100 amps)
 Opto U23 .......................... Contactor
 D24 ................................... PWM (Chopper ON)
 Opto U22 .......................... Pilot Arc Relay ON
 D43 ................................... PAT ON (Blinks during a START)
 Opto U36/U37 ................... Impulse/RHF (Blinks during a START)
The following DSP Indicators should illuminate with an arc transfer:
 Opto U31 .......................... Postflow
 Opto U28 .......................... Plasma
 D41 ................................... Motion
The following LEDs should turn OFF after the Motion Indicator turns ON:
 Opto U36/U37 ................... Impulse/RHF
 Opto U27 .......................... Preflow
 D43 ................................... PAT
When the START signal is removed, OPTO U30 (Vent) will illuminate. It will then go out
with the rest of the cut cycle indicators.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-6