Configuring Device As Udp Listener To Accept Udp Client Connections - Multitech MTC-EV3 User Manual

Table of Contents

Advertisement

CONFIGURING AND COMMUNICATING WITH YOUR DEVICE
AT!STATUS
3.
Configure socket parameters
Enter:
AT#SCFG=1,1,300,240,600,50
4.
Activate context one
Enter:
AT#SGACT=1,1
5.
Create UDP connection to Server port
Enter:
AT#SD=1,1,####,"###.##.###.##" where #### is the server port and ###.##.###.## is the IP number.
The device responds with OK, which indicates a successful connection. You can send and receive data through the
socket connection.
Exit Data Mode and Close Connection
To exit data mode and close the socket:
Enter the escape sequence: +++
To close Socket 1, enter: AT#SH=1
The device responds with OK.
To close the data connection, enter:AT#SGACT=1,0
The device responds with OK.

Configuring Device as UDP Listener to Accept UDP Client Connections

To configure the device as a UDP client:
1.
Check signal strength.
Enter:
AT+CSQ
2.
Verify device is registered on the cellular network.
Enter:
AT!STATUS
3.
Configure socket parameters
Enter:
AT#SCFG=1,1,300,240,600,50
4.
Activate context one
Enter:
AT#SGACT=1,1
5.
Set firewall rule to accept connections:
AT#FRWL=1,"###.##.###.#","###.##.###.#" where ###.##.###.# represents the IP range. For example:
AT#FRWL=1,"204.26.122.1","204.26.122.255"
6.
Set connection ID 1 for UDP listening mode on port 7000.
Enter:
26
®
MultiConnect
Cell MTC-EV3 User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiconnect cell

Table of Contents