Troubleshooting - Lincoln Electric STATIFLEX 400-MS User Manual

Self-cleaning stationary welding fume filter
Table of Contents

Advertisement

Available languages

Available languages

6.2.1
Filter
Replace the filter:
- when damaged;
- when the extraction capacity remains insufficient;
- when the indicator keeps blinking, with the cleaning
mechanism running.
You must learn from experience when to replace the filter,
since the life span of the filter strongly depends on the
composition of the welding fumes, the humidity, etc.
• Remove the filter cover (Fig. 6.1 A) by loosening the star
knob and loosening the four clips.
• Remove the filter (Fig. 6.1 B). It is recommended to clean
the filter compartment using an industrial vacuum cleaner.
• Position the new filter and mount the filter cover.
Fig. 6.1
6.2.2
Prefilter box
Replace the steel mesh filter:
- when it is clogged or saturated and cannot be cleaned using
a vacuum cleaner; or
- when it has been damaged.
In case the steel mesh filter has been damaged, it is
recommended to also replace the filter cartridge.
To replace the steel mesh filter, proceed as follows:
• Disconnect the extraction fan from the input power.
• Loosen the two clips and remove the filter cover.
• Remove the steel mesh filter.
• If required by federal, state and/or local regulations and
guidelines, conceal prefilter in appropriate bag, e.g. plastic
bag.
Spare prefilters are supplied in a plastic bag. This
bag can be used to pack and dispose of the used
prefilter.
• Clean the inside of the prefilter box with an industrial
vacuum cleaner.
• Install a new steel mesh filter.
• Replace the filter cover and fasten the two clips.
6.2.3
Dust barrel
Empty the dust barrel (Fig. 6.2):
- when full;
- (preferably) upon replacement of the filter.
0507320020/061112/E Statiflex 400-MS
Fig. 6.2
7

tROubLEShOOtiNg

• If the machine does not function (correctly), consult the
checklist below to see if you can remedy the error yourself.
Should this not be possible, contact your supplier.
waRNiNg
Always switch OFF the connected extraction fan
before carrying out the activities below. First read
the maintenance regulations at the beginning of this
manual.
A number of problems in the checklist below can
also be caused by defects in the connected
equipment. This manual only deals with problems
and solutions directly related to the product itself.
problem
cause
Extraction remains
Incorrect direction of
insufficient.
rotation of extraction
fan.
Filter clogged or
saturated.
Steel mesh filter
inside prefilter box
clogged.
Cleaning mechanism
defective.
Dust or smoke from
Filter ripped or
outlet opening.
placed incorrectly.
Dust or smoke from
Outlet(s) blocked.
inlet opening.
Filter cartridge
clogged.
Steel mesh filter
inside prefilter box
clogged.
Dust or smoke from
Sealing of dust
dust barrel.
barrel leaky.
Solution
Change the directions
of rotation. See the
corresponding manual.
Replace filter.
Clean (see section 6.1)
or replace (see section
6.2.2) the steel mesh
filter.
Repair cleaning
mechanism.
Replace filter or place it
correctly.
Remove obstructions
from the outlet
opening(s) and/or
connected ductwork.
Replace filter cartridge
(see section 6.2.1).
Clean (see section 6.1)
or replace (see section
6.2.2) the steel mesh.
Replace sealing of dust
barrel.
EN - 9