washing up liquid are gone.
4. Refi ll with tap water with a maximum hardness of 10º only, replace the cap, do not overtighten.
5. Do not use a decalcifi er when cleaning the appliance, this may shorten the lifetime of the smoke unit.
Sump
1. Press Switch 'A' to the 'OFF' (0) position
2. Gently pull the drawer out as far as possible. (See Fig.3)
3. Remove the water tank by lifting upwards.
4. Disconnect the electrical connector, located on the left side of the sump, by fi rst loosening the two retaining screws
and gently withdrawing the connector. (See Fig.8)
5. Release the lower sump locking tabs by turning 90º, this allows the sump to be lifted completely from its location.
(See Fig.9)
6. Gently lift up the sump assembly, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
(See Fig.10)
7. Release the two upper sump locking tabs by turning 90º, then lift off the sump lid. (See Fig.11)
8. Carefully tilt, as shown, so that the liquid drains out of the sump. (See Fig.12)
9. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all surfaces
including the metal discs and the rubber seal located in the top grooved surface. Do not remove the rubber seals.
(See Fig.13 and 14)
10. When cleaned, thoroughly rinse the sump with clean water.
11. Clean the outlet surface of the sump lid with the brush and fl ush out thoroughly with water. (See Fig.15 & 16)
12. Reverse the above steps to reassemble.
Air fi lter.
1. Gently pull the drawer out as far as possible. (See Fig.3).
2. Press Switch 'A' to the 'OFF' (0) position (See Fig.2)
3. Remove the tank and place in a sink with the cap facing upwards.
4. Gently slide upwards the air fi lter plastic holder. (See Fig.17)
5. Remove the fi lter combination from the plastic holder.
6. Gently rinse with water in the sink and dry with fabric towel before returning.
7. Replace the fi lter combination making sure that the course black fi lter is in contact with the plastic holder. (See
Fig.18)
8. Replace the tank.
9. Press Switch 'A' to the 'ON' ( I ) position (See Fig.2).
10. Close the drawer fully.

Additional Information

Recycling.
For electrical products sold within the European Community. At the end of the electrical products useful life it should
not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or
retailer for recycling advice in your country.
After Sales Service
Should you require after sales service, please get in touch with the supplier through whom you purchased the
appliance.
9

Advertisement

Table of Contents
loading

Table of Contents