Wiring - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2.3

Wiring

1.
For the wiring, strip off the sheath of a cable, and use it with a crimp terminal. For a single wire, strip off the sheath of the
wire and apply directly. Insert the crimp terminal or the single wire into a socket of the terminal.
Strip the signal wires as follows. If too much of the wire is stripped, a short circuit may occur with neighboring wires. If not
enough of the wire is stripped, wires may become loose and fall out. Twist the stripped end of wires to prevent them from
fraying. Do not solder them. Use a crimp terminal as necessary.
L (mm)
Terminals A, B, C
6
Other than the above
5
Crimp the terminals on the wire.
Insert the wire into a crimp terminal, making sure that 0 to 0.5 mm of the wire protrudes from the end of the sleeve.
Check the condition of the crimp terminals after crimping. Do not use the crimp terminals of which the crimping is
inappropriate, or the face is damaged.
CAUTION
• After wiring, wire offcuts must not be left in the inverter. Wire offcuts can cause an alarm, failure or malfunction.
24
INSTALLATION AND WIRING
Wire strip length
L
Damaged
Crumpled tip
Unstranded
wires
Wires are not inserted
into the sleeve

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e8te7

Table of Contents